Troubleshooting Tips. | ge.com |
Troubleshooting Tips.
Save time and money! Review the chart below first and you may not need to call for service.
Problem |
| Possible Causes | What To Do |
|
Air conditioner |
| The air conditioner | • Make sure the air conditioner plug is pushed completely | |
does not start |
| is unplugged. | into the outlet. |
|
|
|
|
|
|
|
| The fuse is blown/circuit | • Check the house fuse/circuit breaker box and replace |
|
|
| breaker is tripped. | the fuse or reset the breaker. |
|
|
|
|
|
|
|
| Power failure. | • The unit will automatically |
|
|
|
| used after the power is restored. |
|
|
|
| • There is a protective time delay (approximately |
|
|
|
| 3 minutes) to prevent tripping of the compressor |
|
|
|
| overload. For this reason, the unit may not start |
|
|
|
| normal cooling for 3 minutes after it is turned |
|
|
|
| back on. |
|
|
|
|
| |
|
| The current interrupter | • Press the RESET button located on the power cord plug. | |
|
| device is tripped. | • If the RESET button will not stay engaged, discontinue |
|
|
|
| use of the air conditioner and contact a qualified service | |
|
|
| technician. |
|
|
|
|
|
|
Air conditioner does not |
| Airflow is restricted. | • Make sure there are no curtains, blinds or furniture |
|
cool as it should |
|
| blocking the front of the air conditioner. |
|
|
|
|
|
|
|
| The temp control may not | • In COOL mode, press the Decrease ▼ pad. |
|
|
| be set correctly. |
|
|
|
|
|
|
|
|
| The air filter is dirty. | • Clean the filter at least every 30 days. |
|
|
|
| See the Operating Instructions section. |
|
|
|
|
| |
|
| The room may have been hot. | • When the air conditioner is first turned on, you need to | |
|
|
| allow time for the room to cool down. |
|
|
|
|
|
|
|
| Cold air is escaping. | • Check for open furnace floor registers and cold air |
|
|
|
| returns. |
|
|
|
| • Set the air conditioner’s vent to the closed position. |
|
|
|
|
|
|
|
| Cooling coils have iced up. | • See “Air conditioner freezing up” below. |
|
|
|
|
|
|
Air conditioner |
| Ice blocks the air flow and | • Set the controls at HIGH (F3) FAN or HIGH (F3) COOL and |
|
freezing up |
| stops the air conditioner | set the thermostat to a higher temperature. |
|
|
| from cooling the room. |
|
|
|
|
|
|
|
The remote control |
| The batteries are inserted | • Check the position of the batteries. They should be |
|
is not working |
| incorrectly. | inserted in the opposite (+) and |
|
|
|
|
|
|
|
| The batteries may be dead. | • Replace the batteries. |
|
|
|
|
|
|
Water drips outside |
| Excessively hot and | • This is normal. |
|
|
| humid weather. |
|
|
|
|
|
| |
Water drips indoors |
| The air conditioner is not | • For proper water disposal, make sure the air conditioner | |
|
| tilted to the outside. | slants slightly from the case front to the rear. |
|
|
|
|
|
|
Water collects in |
| Moisture is removed from | • This is normal for a short period in areas with little |
|
base pan |
| indoor air and drains into | humidity; normal for a longer period in very humid areas. | |
|
| rear of a cabinet where a fan |
|
|
|
| blows it against the outdoor |
|
|
|
| condenser coil. |
|
|
|
|
|
|
|
TIMER feature not |
| A power outage or interruption | • In the case of a power outage or interruption, the unit |
|
working properly |
| occurred. | TIMER feature will reset to the original setting. You may | |
|
|
| need to set a new time if desired. | 11 |
|
|
|
|
|
Safety Instructions Operating Instructions Installation Instructions Troubleshooting Tips Consumer Support