1WINDOW REQUIREMENTS

Installation Instructions

1WINDOW REQUIREMENTS

These instructions are for a standard double-hung window. You will need to modify them for other types of windows.

The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions.

All supporting parts must be secured to firm wood, masonry or metal.

The electrical outlet must be within reach of the power cord.

12min.

26to 3938

(With accordion panels)

22min.

(Without accordion panels)

2STORM WINDOW REQUIREMENTS

A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly.

To adjust for this, attach a piece of wood to the stool.

WOOD PIECES–

WIDTH: 2

LENGTH: Long enough to fit inside the window frame.

THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2higher than the top of the storm window frame.

Attach securely with nails or screws provided by the installer.

Wood

1/2higher

 

than frame

Stool

 

Storm window frame

3PREPARE THE WINDOW

ACut the window sash seal to the window width and stick the adhesive side to the bottom of the sash.

Window

2STORM WINDOW REQUIREMENTS3PREPARE THE WINDOWsash seal

INSIDE

BMark the centerline of the sill. Measure

and mark the location for the support bracket 1to the left of the centerline.

Sill

OUTSIDE

L

INSIDE

C

 

Center line

1left of center line

Stool

4PREPARE THE AIR CONDITIONER

Insert the frames for the accordion panels into the bottom mounting rail and the top frame guides. Attach the accordion panels to the side of the case by pressing them onto the mounting tabs.

9