GE AGN05, AGQ05, AGV05, AGS05 1WINDOW REQUIREMENTS, 2STORM WINDOW REQUIREMENTS, 3PREPARE THE WINDOW

Models: AGN05 AGS05 AGV05 AGQ05

1 36
Download 36 pages 37.94 Kb
Page 11
Image 11
1WINDOW REQUIREMENTS

Installation Instructions

1WINDOW REQUIREMENTS

These instructions are for a standard double-hung window. You will need to modify them for other types of windows.

The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions.

All supporting parts must be secured to firm wood, masonry or metal.

The electrical outlet must be within reach of the power cord.

12min.

21to 35

(With accordion panels)

18min.

(Without accordion panels)

2STORM WINDOW REQUIREMENTS

A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly.

To adjust for this, attach a piece of wood to the stool.

WOOD PIECES–

WIDTH: 2

LENGTH: Long enough to fit inside the window frame.

THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2higher than the top of the storm window frame.

Attach securely with nails or screws provided by the installer.

Wood

1/2higher

 

than frame

Stool

 

Storm window frame

11

3PREPARE THE WINDOW

ACut the window sash seal to the window width and stick the adhesive side to the bottom of the sash.

Window 2STORM WINDOW REQUIREMENTSsash seal

INSIDE

BMark the centerline of the sill. Measure

and mark the locations for the support brackets 712from both sides of the centerline.

CPlace 2 support brackets on the sill,

against the back edge of the stool with their holes centered on each 712mark.

Type B screw

Inside

Stool

Sill

Support bracket

Outside Support bracket

DAttach them to the sill with one Type B screw through each support bracket.

Page 11
Image 11