Through-the-wall installation.

Instructions Safety Instructions

Through-the-wall installation.

Read these instructions completely and carefully.

1

Preparation of the Opening in the Wall

Make certain a wall receptacle is available close to

the hole location or make arrangements to install

a receptacle.

The cord length for the 115-volt models is 72″ to the right and 47″ to the left.

For the 230/208-volt models the cord length is 65″ to the right and 39″ to the left.

Installation Instructions Care and Cleaning Operating

Support Requirements for the Air ConditionerInside 2

Support Requirements for the Air Conditioner

The air conditioner wall case may be installed flush with the inside wall or flush with the outside wall.

The finished sides of the opening should be structural wall members.

Lintel—Use a lintel in brick veneer and brick and block types of wall to support the bricks or blocks above the opening. Do not allow the wall case to be used in lieu of a lintel.

Flashing—Install flashing (drip rail) as shown to prevent water from dripping inside the wall and down the outside of the building.

Brick veneer

 

 

 

 

 

 

 

 

 

 

 

 

Lintel angle

 

 

 

 

 

 

 

 

 

 

 

 

(if required)

 

 

 

 

 

Plaster

 

 

 

 

 

 

Caulking

 

 

 

 

 

line

(on all 4 sides

 

 

 

 

 

 

on the outside

 

 

 

 

 

Trim

of the case)

 

 

 

 

 

 

 

 

 

 

molding

 

 

 

 

 

 

 

 

 

 

 

 

(if desired)

 

 

 

 

 

 

Room side

 

 

 

Caulking

 

 

 

(above &

 

 

 

below the

 

 

 

flashing)

Flashing

 

 

 

 

 

 

 

 

 

 

 

 

(drip rail)

 

 

 

 

 

 

1/4min. extension Outside inside the wall from

the trim molding

Consumer Support Troubleshooting Tips

Manual backgroundManual background 3

Support Requirements for the Air Conditioner

Mortar between the case and the brick all around the case may be undercut at about 45° for improved caulking.

 

Inside

 

Top of case

 

Outside

Caulking

Undercut

 

mortar