3ELECTRICAL CONNECTIONS

Electrical Requirements

120-volt, 60 Hertz, properly grounded branch circuit protected by a 15-amp or 20-amp circuit breaker or time delay fuse.

Extension Cord Cautions

Because of potential safety hazards associated with certain conditions, we strongly recommend against the use of an extension cord. However, if you still elect to use an extension cord, it is absolutely necessary that it be a UL-listed, 3-wire grounding-type appliance extension cord and that the current carrying rating of the cord in amperes be equivalent to, or greater than, the branch circuit rating.

Grounding

IMPORTANT—(Please read carefully)

FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.

Preferred Method

Ensure proper ground exists before use

The power cord of this appliance is equipped with a

3-prong (grounding) plug which mates with a standard three-prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance.

The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded.

Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a properly grounded three-prong wall receptacle.

DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD (GROUND) PRONG FROM THE POWER CORD.

A word about GFCI’s – GFCI’s are not required or recommended for gas range receptacles.

Ground Fault Circuit Interrupters (GFCI’s) are devices that sense leakage of current in a circuit and automatically switch off power when a threshold leakage level is detected. These devices must be manually reset by the consumer. The National Electrical Code requires the use of GFCI’s in kitchen receptacles installed to serve countertop surfaces. Performance of the range will not be affected if operated on a GFCI-protected circuit

but occasional nuisance tripping of the GFCI breaker is possible.

3ELECTRICAL CONNECTIONS (CONT.)

A.Usage Situations where Appliance Power Cord will be Disconnected Infrequently.

An adapter may be used only on a 15-amp circuit. Do not use an adapter on a 20-amp circuit. Where local codes permit, a TEMPORARY CONNECTION may be made to a properly grounded two-prong wall receptacle by the use of a UL-listed adapter, available at most hardware stores. The larger slot in the adapter must be aligned with the larger slot in the wall receptacle to provide proper polarity in the connection of the power cord.

Temporary Method

(Adapter plugs not permitted in Canada)

Align large prongs/slots

Ensure proper ground and firm connection before use

CAUTION: Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal, and not insulated, and the wall receptacle is grounded through the house wiring. The customer should have the circuit checked by a qualified electrician to make sure the receptacle is properly grounded.

When disconnecting the power cord from the adapter, always hold the adapter with one hand. If this is not done, the adapter ground terminal is very likely to break with repeated use. Should this happen, DO NOT USE the appliance until a proper ground has again been established.

40

Page 40
Image 40
GE EGR3000 installation instructions Electrical Connections, Electrical Requirements

EGR3000 specifications

The GE EGR3000 is a cutting-edge gas turbine engine designed to meet the demands of modern power generation and transportation applications. This innovative engine showcases a range of advanced features and technologies that enhance its performance, efficiency, and reliability.

One of the key characteristics of the EGR3000 is its exceptional efficiency. The engine employs an advanced thermodynamic cycle, which incorporates a high compression ratio and an innovative cooling design. This efficiency is particularly important in reducing fuel consumption and emissions, making it an environmentally friendly option compared to traditional gas turbines. The EGR3000 boasts a thermal efficiency rating that places it among the highest in its class.

The EGR3000 utilizes a dual-fuel capability, allowing it to operate on a variety of fuels. This flexibility is crucial for operators looking to optimize their fuel use based on availability and cost, adding to the engine's versatility. Additionally, the engine is designed to accommodate both natural gas and liquid fuels, thereby enhancing its operational range.

Another notable feature is the engine's advanced modular design. This allows for easier maintenance and quicker turnaround times, minimizing downtime and operational costs for power plants and industrial facilities. The modular components can be replaced or serviced individually, which simplifies maintenance procedures and enhances overall reliability.

In terms of technology, the EGR3000 incorporates sophisticated materials and coatings that improve thermal resistance and durability. High-performance blades and combustion chambers are designed to withstand extreme temperatures, resulting in longer service life and reduced maintenance frequency. The engine also employs digital control systems that optimize performance parameters in real-time, ensuring peak efficiency under varying load conditions.

Emissions control is a critical aspect of the EGR3000's design. It features advanced combustion technology that minimizes NOx and CO2 emissions, aligning with stringent environmental regulations. The engine's design enables it to operate with lean-burn technology, further supporting reduced environmental impact.

Overall, the GE EGR3000 stands out as a powerful and efficient gas turbine solution. Its combination of high efficiency, fuel flexibility, modular design, and advanced emission control technologies makes it an ideal choice for various applications, including power generation and industrial processes. As energy demands continue to evolve, the EGR3000 positions itself as a reliable and forward-thinking solution for today’s energy landscape.