INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY

INSTRUCTIONS

Installation of this range must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1, latest edition. In Canada, installation must conform with the current Natural Gas Installation Code, CAN/CGA- B149.1 or the current Propane Installation Code, CAN/CGA-B149.2, and with local codes where applicable.

This range has been design-certified by the American Gas Association according to ANSI Z21.1, latest edition and Canadian Gas Association according to CAN/CGA-1.1 latest edition. As with any appliance using gas and generating heat, there are certain safety precautions you should follow. You will find these precautions in the Important Safety Instructions in the front of this guide. Read them carefully.

Have your range installed by a qualified installer.

Your range must be electrically grounded in accordance with local codes or, in the absence of local codes, in accordance with the National Electrical Code (ANSI/NFPA 70, latest edition). In Canada, electrical grounding must be in accordance with the current CSA C22.1 Canadian Electrical Code Part 1 and/or local codes. See Electrical Connections in this section.

Before installing your range on linoleum or any other synthetic floor covering, make sure the floor covering can withstand 180°F. without shrinking, warping or discoloring. Do not install the range over carpeting unless a sheet of 1/4″ thick plywood or similar insulator is placed between the range and carpeting.

Make sure the wall coverings around the range can withstand heat generated by the range up to 200°F.

Avoid placing cabinets above the range. To reduce the hazard caused by reaching over the open flames of operating burners, install a ventilation hood over the range that projects forward at least 5″ beyond the front of the cabinets.

The ventilating hood must be constructed of sheet metal not less than 0.0122″ thick. Install above the cooktop with a clearance of not less than 1/4″ between the hood and the underside of the combustible material or metal cabinet.

The hood must be at least as wide as the appliance and centered over the appliance. Clearance between the cooking surface and the ventilation hood surface MUST NEVER BE

LESS THAN 24 INCHES.

36

EXCEPTION: Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance.

If cabinets are placed above the range, allow a minimum clearance of 30″ between the cooking surface and the bottom of unprotected cabinets.

If a 30″ clearance between cooking surface and overhead combustible material or metal cabinets cannot be maintained, protect the underside of the cabinets above the cooktop with not less than 1/4″ insulating millboard covered with sheet metal not less than 0.0122″ thick.

Clearance between the cooking surface and protected cabinets MUST NEVER BE LESS THAN 24 INCHES. The vertical distance from the plane of the cooking surface to the bottom of adjacent overhead cabinets extending closer than 1″ to the plane of the range sides must not be less than 18″. (See Dimensions and Clearances illustration in this section.)

CAUTION: Items of interest to children should not be stored in cabinets above a range or on the backsplash of a range—children climbing on the range to reach items could be seriously injured.

WARNING

All ranges can tip and injury could result. To prevent accidental tipping of the range, attach an approved Anti-

Tip device to the wall. (See Installing

the Anti-Tip Device in this section.) To check if the device is installed and engaged properly, carefully tip the

range forward. The Anti-Tip device should engage and prevent the range from tipping over.

If you pull the range out from the wall for any reason, make sure the Anti-Tip device is engaged when you push the range back against the wall.

For your safety, never use your range for warming or heating the room. Your oven and cooktop are not designed to heat your kitchen. Top burners should not be operated without cookware on the grate. Such abuse could result in fire and damage to your range and will void your warranty.

Do not store or use combustible materials, gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Explosions or fires could result.

Do not use oven for a storage area. Items stored in the oven can ignite.

Do not let cooking grease or other flammable materials accumulate in or near the range.

Page 36
Image 36
GE EGR3001, JR EGR3000, JGBP40 manual Important Safety Instructions

JGBP40, JR EGR3000, EGR3001 specifications

The GE EGR3001, JR EGR3000, and JGBP40 are three innovative industrial equipment models from General Electric, renowned for their efficiency and advanced engineering.

The GE EGR3001 represents a significant advancement in gas turbine technology. This model is designed for optimal performance in combined cycle power plants, where its high efficiency helps to reduce fuel consumption and greenhouse gas emissions. The EGR3001 features an advanced combustor design that facilitates low emissions and enhances fuel flexibility, allowing it to operate on various fuels, including natural gas and liquid fuels. This flexibility is crucial in today's energy markets, where energy source availability may fluctuate.

The EGR3001 is also equipped with sophisticated control systems that provide reliable performance even under varying load conditions. Its modular design simplifies maintenance, allowing for faster service times and lower operational costs. Additionally, the EGR3001's robust construction ensures durability and longevity, making it an excellent investment for power generators.

The JR EGR3000 is another remarkable model in GE's lineup, focusing on integration and performance in industrial settings. This unit combines the features of a gas turbine with superior steam generation capabilities. The JR EGR3000 prides itself on its compact design, which facilitates easy installation without compromising performance. It features advanced aerodynamics and heat recovery systems that maximize output while minimizing fuel consumption.

A key highlight of the JR EGR3000 is its digital twin technology, which allows operators to simulate and analyze performance in real-time. This technology provides valuable insights for maintenance planning and operational efficiency, leading to decreased downtime and optimally managed assets.

The JGBP40 is a unique offering, primarily designed for industrial applications requiring higher efficiency and reliability. It integrates advanced gearbox technology with high-speed turbine operations, facilitating increased torque and power output. The JGBP40 is designed for versatility, able to support various applications across different industries.

Its design incorporates advanced materials to withstand high-stress conditions, thereby increasing operational lifespan. The model also features smart diagnostics and predictive maintenance capabilities, allowing operators to monitor health and performance efficiently. This proactive approach minimizes unplanned outages and enhances overall productivity.

In summary, the GE EGR3001, JR EGR3000, and JGBP40 are testament to General Electric’s commitment to innovation, efficiency, and reliability in industrial equipment. Their advanced features and technologies not only optimize performance but also address modern energy challenges, making them essential assets for electricity producers and industrial users alike.