Step-by-step installation instructions.

Mounting Bracket to Cabinet Wall

The bracket can be used as a template for marking the location of the mounting screws. When determining the location of the bracket make sure you leave 1-1⁄2″ to 2″ of free area under the sumps to allow for sump removal and enough space on either side to make the tubing connections.

Make Tubing Connections

 

Run the length of 3⁄8″ tubing, connected to the bottom of faucet, to the filter system outlet, Fig.1 in the

1

Installation Overview section. Allow enough slack in the tubing to be able to place the system on the floor in front

 

 

of the sink. Measure and cut the end of the tubing square.

 

Slide a compression nut onto the end of the tubing and push a tubing insert into the tubing.

2

 

Connect the tubing and tighten the compression nuts securely.

3

 

Repeat the preceding steps to connect a length of tubing between the filter system inlet and the water

4

 

supply/saddle valve, Fig. 1 in the Installation Overview section.

 

Fig. 4

 

7-9 ⁄ 1 6

 

 

 

 

 

 

Tubing

 

 

 

 

 

 

connector

 

Mounting

 

 

 

 

 

bracket

 

 

 

Mounting

 

 

 

 

 

 

 

Tubing

 

 

 

screws

 

 

 

 

 

 

connector

 

 

 

 

 

Sump

 

 

 

 

Sump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Filter II

 

Filter I

 

 

 

 

1 -1 ⁄ 2 to 2

Filter Cartridge Installation or Replacement

CAUTION: Never remove sumps with water pressure in the Water Filtration system.

1 Close the water supply/saddle valve (Fig. 1 and 2A) to the filter. Open the filtered water faucet.

2 Turn the sump off of the filter head as shown (use the sump wrench provided). Be careful, the sump is full of water. Locate and save the large o-ring seal. Remove and discard the used filter cartridge.

3 Be sure the inside of the sump is clean. Thoroughly wash with hot, soapy water and rinse.

4 Remove the wrapper and labels from the new filter cartridge and insert the filter cartridge in the sump. Some cartridges fit either way, while others fit only one way. Observe markings on the end of the cartridge. The sediment (FXUSB) filter cartridge should always be placed in the Filter I sump.

5 Lightly lubricate the o-ring seal, in the sump, with clean silicone grease. Be sure it is fully seated in its groove.

6 Hold the sump up to the filter head, aligning the center hole in the cartridge with the protrusion on the bottom of the head.

NOTE: If the sump will not tighten up to the head, you may have the cartridge in upside down. Take the cartridge out and check the markings on the end of the cartridge for correct orientation.

7 Being careful not to cross-thread, turn the sump onto the filter head and hand tighten securely (see Fig. 5).

10Make Tubing Connections CAUTION: If using the sump wrench to tighten the sump, do not overtighten.