Installation Instructions.

Important Installation Recommendations

Read entire manual. Failure to follow all guides and rules could cause personal injury or property damage.

Check with your local public works department for plumbing codes. You must follow their guides as you install the Water Filtration system.

Use the Water Filtration system on a potable, safe-to-drink, home COLD water supply only. The filter cartridges will not purify water or make unsafe water safe to drink. DO NOT use on HOT water (100° F. max.).

Protect the Water Filtration system and piping from freezing. Water freezing in the system will damage it.

Your Water Filtration system will withstand up to 125 psi water pressure. If your house water supply pressure is higher than 100 psi during the day (it may reach higher levels at night), install a pressure reducing valve before the system.

WARNING: Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. The water should be tested periodically to verify that the system is performing satisfactorily. Small parts remaining after the installation could be a choke hazard. Discard safely.

Safety Instructions Operating Instructions

Tools and Materials Required for Installation

Slotted and Phillips screwdrivers

Pliers and adjustable jaw wrench

Hand or battery powered drill and 1⁄4″ bit (saddle valve installation)

Electric drill and drill bit to drill 1″−1-1⁄4″ hole (type as required) if mounting hole is needed for faucet

CAUTION: To avoid damaging the sink, consult a qualified plumber or installer for drilling procedures. Special drill bits may be needed for porcelain or stainless steel.

Contents included with the product:

Water filter assembly, including mounting bracket and screws

Product Literature (Owner’s Manual and Installation, Product Data Sheet, Owner Product Registration Card)

Water supply/saddle valve

Filtered water faucet, for sink or countertop mounting

3⁄8″ tubing and fittings to make all needed connections

Sump wrench

Installation Instructions

Installation Overview

Fig. 1

Locate the drinking water

 

 

 

 

 

 

system on the cold water

 

 

 

 

 

 

 

 

 

 

 

 

supply pipe, under the

 

 

 

 

 

 

 

Sink

 

kitchen and/or bathroom

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sink, to filter the cold

 

 

 

 

 

 

drinking water.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot Cold

Shutoff valve

NOTE:To change the filter cartridge, you must turn off the water. A nearby shutoff valve is convenient. Most sinks already have shutoff valves on the supply pipes.

Filtered

 

 

 

water faucet

Washer

 

 

 

Adapter

 

 

 

 

 

Water

 

Nut

 

out

 

Tubing

 

 

Water supply/saddle valve

 

Water

Mounting

 

in

 

screw (2)

 

 

 

 

Insert

 

 

 

Nut

 

 

 

Tubing

 

Filter II

 

 

 

 

 

Filter I

 

 

 

 

1-1/2to 2

7

Troubleshooting Tips

Customer Service

Page 7
Image 7
GE GXUT03B Installation Instructions, Important Installation Recommendations, Installation Overview, Troubleshooting Tips

GXUT03B, GNUT03B specifications

The GE GNUT03B and GXUT03B are advanced electronic units designed to enhance operational efficiency across various industrial applications. These models are part of General Electric's extensive portfolio, known for their reliability and innovative technology.

One of the standout features of the GNUT03B and GXUT03B is their robust communication capabilities. Both units support multiple protocols, which ensures seamless integration into existing systems. This interoperability allows for easy adaptability in complex environments including manufacturing plants, energy sectors, and smart grid systems. The units can communicate with different devices, controllers, and software applications, facilitating real-time data exchange and monitoring.

In terms of processing power, the GNUT03B and GXUT03B are equipped with high-performance processors that enable fast data processing and analysis. This capability is crucial for industries where timely decision-making impacts productivity and safety. The user-friendly interface of these units provides operators with intuitive access to their features, allowing for easy setup and navigation.

Another significant characteristic is the units' built-in redundancy features. These ensure continuous operation, minimizing downtime that can be costly in industrial settings. The GNUT03B and GXUT03B also include fail-safe mechanisms designed to protect critical operations, making them suitable for mission-critical applications.

Energy efficiency is another important aspect of these models. They are designed not only to provide high performance but also to reduce overall energy consumption. This not only leads to cost savings but also promotes sustainability, aligning with the growing emphasis on environmentally friendly practices in industry.

The GNUT03B and GXUT03B boast extensive data storage capabilities, enabling them to manage large volumes of information. This is particularly beneficial for applications requiring historical data analysis, predictive maintenance, and performance optimization. Their advanced analytics capabilities assist organizations in making data-driven decisions to enhance operational efficiency and reduce operational risks.

Finally, the durability and rugged design of these units make them suitable for harsh environments. They have been engineered to withstand extreme temperatures, vibration, and dust, which ensures a long operational life and minimizes the need for frequent replacements or repairs.

Overall, the GE GNUT03B and GXUT03B represent a fusion of cutting-edge technology and practical functionality, making them indispensable tools for modern industrial operations. With their impressive features and characteristics, they are well-equipped to meet the demands of an ever-evolving industrial landscape.