GE JGBP85 A Conversion & Orifices Information, Bake Burner Adjustments, Broil Burner Adjustments

Models: JGBP30 A JGBP26 A JGBP35 A JGBP86 A JGBP90 A JGBP79 A JGBP85 A

1 34
Download 34 pages 46.28 Kb
Page 14
Image 14
CONVERSION & ORIFICES INFORMATION

CONVERSION & ORIFICES INFORMATION

BAKE BURNER

ADJUSTMENTS

Loosen

Air Adjustment

Shutter

Air Adjustment

Shutter

Loosen

BROIL BURNER ADJUSTMENTS

6Open the bake and broil air shutter adjustments as far as possible and adjust later if necessary.

Beneath the bake and broil burner orifice hoods are LP orifice needles. To convert to L.P. tighten the orifice hoods against the orifice needle until the hoods are snug (2-2½ turns). DO NOT OVER TIGHTEN. Check the burners for proper flame adjustment. The burner flame should have approximately 1" blue cones. With most LP gas, small yellow tips at the end of outer cones are normal. flames should not lift off burner ports. If lifting is observed, gradually reduce the air shutter opening until flames are stabilized.

BURNER OUTPUT RATINGS; BTU/HR

NATURAL GAS with 4" W.C.P.

Burner

BTU Rate

Orifice Size

 

 

 

LF, RF

12,000

1.68 mm (III)

 

 

 

LR

9,500

1.50 mm (II)

 

 

 

RR

5,000

1.07 mm (I)

 

 

 

BAKE

16,000

#47 (.0785")

 

 

 

BROIL

13,500

(.069")

 

 

 

175Natural gas surface

N

orifices are marked

III

on top as shown

 

ORIFICE INFORMATION

JGBP85BEA Orifice Charts

TOP BURNER ORIFICES

LR

RR

LF

RF

LP

GAS

Front of Range

The top burner orifices each have a series of marks engraved on the tops of the orifices (I, II, III) to denote their location. The marks appear on both the Natural and LP gas orifices. The location indicated by the marks, is the same for both gases.

See BURNER OUTPUT RATING charts at right for locations.

BURNER OUTPUT RATINGS; BTU/HR

LP (PROPANE) GAS with 10" W.C.P.

Burner

BTU Rate

Orifice Size

 

 

 

 

LF, RF

11,000

.94L mm

(III)

 

 

 

 

LR

9,500

.89L mm

(II)

 

 

 

 

 

RR

5,000

.63L

MM

(I)

 

 

 

 

BAKE

16,000

#56

(.0465")

 

 

 

 

BROIL

12,000

#59

(.041")

 

 

 

 

 

90LP gas surface

L

orifices are marked

III

on top as shown

 

SMALLER ORIFICES FOR HIGHER ELEVATIONS

Burner

Size

Part Number

L.P.

Natural

 

 

 

 

 

LF & RF

1.65 mm

WB02X9841

 

 

 

 

 

 

 

LF & RF

.84 mm

WB02K0022

 

 

 

 

 

 

 

LR

1.44 mm

WB06K0094

 

 

 

 

 

 

 

LR

.73 mm

WB19K5000

 

 

 

 

 

 

 

IMPORTANT NOTE: Always consult the Technical Service literature (mini-manual) enclosed with the appliance for model specific conversion information

– 12 –

LP ORIFICE COLOR ID

Burner

BTU Rate

Color

 

 

 

LF & RF

11,000 BTU

Blue / Magenta

 

 

 

LR

9,500 BTU

Blue / Brown

 

 

 

RR

5,000 BTU

Blue / Blue

 

 

 

Paint color codes have been added to the sides of the LP orifices to aid in identifying the proper orifice location during conver- sion.