GE JKP90 installation instructions Installation Instructions, For JTP90, PT970 models only

Models: JTP90 JKP90

1 24
Download 24 pages 49.23 Kb
Page 5
Image 5
For JTP90, PT970 models only.

Installation Instructions

A

Cutout for 30(76.2 cm) Built-In Oven with Microwave models only

For JTP90, PT970 models only.

Allow 11/16(1.8 cm) for overlap of oven over side edges of cutout

Allow a minimum of 21

(53.3 cm) for clearance to adjacent corners, drawers, walls, etc.

when door is open

21(53.3 cm)

Cabinet

Width

30(76.2 cm)

Cutout Width Manual background 28 1/2

(72.4 cm) Min.

285/8

(72.8 cm) Max.

Opening between

inside walls must be at least 28 1/2

(72.4 cm)

wide

20(50.8 cm) Manual background Max.

Junction Box

Location

Cutout

 

 

 

 

Height

 

 

 

 

42 3/16

 

 

 

 

(107.2 cm)

 

 

 

 

28(71.1 cm)

Min.

Min.

 

 

to Bottom of

42 1/4

 

 

Junction Box

(107.3 cm)

 

Max.

 

 

 

 

 

 

 

 

 

Cabinet Width

30(76.2 cm)

Recommended

 

 

Cutout Location

 

 

from Floor

21

5/8(54.9 cm)

Cutout Depth

23

1/2(59.7 cm) Min.

Cutout Width

28

1/2(72.4 cm) Min.

 

28

5/8(72.8 cm) Max.

Cutout Height

42

3/16(107.2 cm) Min.

 

42

1/4(107.3 cm) Max.

NOTE: If the cabinet does

not have a front frame and the sides are less than 3/4(1.9 cm) thick, shim both sides equally to establish the cutout width.

Allow minimum 1

(2.5 cm) for overlap of oven top and 114

(3.2 cm) overlap of bottom of cutout

Recommended cutout location from floor 21 5/8(54.9 cm)

If the cabinet does not have a solid bottom, two braces or runners must be installed level with the bottom of the cutout to support the weight of the oven. The runners and braces must support

255 lbs (115 Kg).

NOTE: If marks, blemishes or the cutout opening are visible above the installed oven, it may be necessary to add wood shims under the runners and front trim until the marks or opening are covered.

Suitable

Bracing to Support Runners

C

L

215/8

(54.9 cm)

Over Centerline

of Cabinet

2x 4

(5 cm x 10 cm) or equivalent runners level with bottom of cutout

5

Page 5
Image 5
GE JKP90 installation instructions Installation Instructions, For JTP90, PT970 models only