![3. POWER SUPPLY](/images/new-backgrounds/66291/6629113x1.webp)
3. POWER SUPPLY
A. CIRCUIT VOLTAGE: This hood must be connected to a supply circuit of the proper voltage and frequency as specified on the rating plate. Wire size must conform to the requirements of the National Electrical Code or the prevailing local code for hoods of this rating. The rating plate is located on the rear wall of the hood.
B. FUSE RATING: 15 amps.
C. Unless otherwise specified by local codes, bring a 15 amp 2 wire circuit with ground to the area of the power supply connection box.
D. USE OF OPTIONAL TOP POWER SUPPLY: The power supply can be attached through the top knockout if desired, but only the top or back knockout shall be opened (See Figs. 8, 9 and 10).
Power supply entrance openings in top
and rear of hood.
NOTE: Use of REAR opening is recommended.
Centerline of hood
11⁄4″
11⁄4″
FIGURE 8
Exhaust outlet connects to 31⁄4″ x 10″ rectangular duct; outlet has TOTAL ADJUSTMENT of 11⁄2″ from side to side to simplify duct alignment.
Exhaust outlet connects to 7″ dia. duct.
Center line |
NOTE: Exhaust outlet can be installed as either TOP or REAR by removing desired knockout. Insert a screwdriver under edge of
Centerline of hood
1/2″ | 3/4″ |
|
knockout. Break tabs and remove knockout with pliers.
Center line
Top exhaust outlet only
Power supply entrance openings
in top and rear of hood. NOTE: Use of REAR opening is recommended.
11⁄4″
FIGURE 10
Power supply | 73⁄4″ | 11⁄4″ |
entrance openings |
|
|
in top and rear of hood. | 11⁄4″ | |
NOTE: Use of REAR |
| |
opening is recommended. | FIGURE 9 |
4.HOOD INSTALLATION A. MECHANICAL
NOTE: When possible, it is more convenient to mount and wire the hood before the base cabinet is put in place.
1.Take out 1 screw and remove the power supply connection box cover located on the underside
of the hood (See Fig. 13 Model: JV327) (See Fig. 12
Models: JN327, JV337 & JV347).
2.To locate the 4 mounting holes, position the hood carefully against the bottom of the wall cabinet and
mark the screw positions through the keyhole slots in the hood. Drill 3/32″ pilot holes for the mounting screws in the small end of the keyhole.
3.Partially drive the 4 mounting screws so that the heads of the screws extend 1/2″ below the bottom of the cabinet. Raise the hood against the bottom of the cabinet, making sure that the heads of the mounting screws protrude through the hole section of the keyhole slots as shown in Fig. 11. Before tightening the mounting screws, attach the power supply cable to the hood. Then push the hood back against the wall and tighten the mounting screws.
Keyhole slots
Screws
FIGURE 11
Direction of
movement for mounting
7