Installation Instructions

A OUTSIDE TOP EXHAUST (Vertical Duct)

INSTALLATION OVERVIEW

A1. Attach Mounting Plate to Wall

A2. Prepare Top Cabinet

A3. Check Damper Operation

A4. Mount Microwave Oven

A5. Adjust Exhaust Adaptor

A6. Connect Ductwork

A1. ATTACH THE MOUNTINGPLATE TOTHE WALL

Attach the plate to the wall using toggle bolts. At least one wood screw must be used to attach the plate to a wall stud.

1Remove the toggle wings from the bolts.

2Insert the bolts into the mounting plate

through the holes designated to gointo drywall and reattach the toggle wings to 34 onto each bolt.

12

To use toggle bolts:

Spacing for Toggles

More Than Wall

Thickness

Mounting

Toggle Wings

Toggle

Plate

Bolt

 

Wall

Bolt End

3Place the mounting plate against the wall and insert the toggle wings into the holes in the wall to mount the plate.

NOTE: Before tightening toggle bolts and wood screw, make sure the tabs on the mounting plate touch the bottom of the cabinet when pushed flush against the wall and that the plate is properly centered under the cabinet.

CAUTION: Be careful to avoid pinching fingers between the back of the mounting plate and the wall.