Installation Instructions

B4. ADAPTING MICROWAVE BLOWER FOR OUTSIDE BACK EXHAUST (cont.)

4Rotate blower unit counterclockwise 180°.

Before Rotation

After Rotation

Back of

Back of

Microwave

Microwave

Oven

Oven

5Gently remove the wires from the grooves. Reroute the wires through grooves on other side of the blower unit.

Before Rerouting

After Rerouting

Wires Routed Through Right Side

Wires Routed Through Left Side

6Roll the blower unit 90° so that fan blade openings are facing out the back of the microwave.

Before Rolling

After Rolling

Back of

Back of

Microwave

Microwave

Oven

Oven

 

7Place the blower unit back into the opening.

AFTER: Fan Blade

Openings Facing Back

End A

End B

CAUTION: Do not pull or stretch the blower unit wiring. Make sure the wires are not pinched.

NOTE: The blower unit exhaust openings should match exhaust openings on rear of microwave oven.

8Secure the blower to the microwave oven using the retaining screw from Step 2.

Blower

Blower

Back ofRetaining Screw

Microwave

Oven

9Slide the exhaust adaptor onto the back of the microwave oven, securing it into the lower locking tabs. Take care to ensure that the damper hinge is installed so that it is at the top and that the damper swings freely. Reinstall the upper blower motor screw through the adaptor and the blower door and into the back of the microwave oven. Close the blower door and secure it using the screw from Step 1.

Blower

Back of

Retaining

Microwave Oven

Screw

 

 

 

 

Guide

Guide

Locking Tabs

Blower Motor

Adaptor

Door Retaining

 

(not shown)

Screw

17