GE Over the Range Microwave Oven manual B1. PREPARING THE REAR WALL FOR OUTSIDE BACK EXHAUST

Models: Over the Range Microwave Oven

1 24
Download 24 pages 50.1 Kb
Page 15
Image 15
B OUTSIDE BACK EXHAUST (Horizontal Duct)

Installation Instructions

B OUTSIDE BACK EXHAUST (Horizontal Duct)

INSTALLATION OVERVIEW

B1.

Prepare Rear Wall

B2.

Attach Mounting Plate to Wall

B3.

Prepare Top Cabinet

B4.

Adjust Blower

B5.

Mount the Microwave Oven

B1. PREPARING THE REAR WALL FOR OUTSIDE BACK EXHAUST

This microwave oven is shipped assembled for top exhaust. You will need the exhaust adaptor for installation in the rear wall opening. To remove the exhaust adaptor from the microwave oven:

F

G

H

I

5

6

Remove tape securing damper.

7

Remove and

 

save screw

Damper

that holds

 

blower plate

 

to microwave.

 

Lift off the blower plate and attached adaptor from the microwave.

1Place the mounting plate against the rear wall and align it with the holes drilled earlier.

2Using a pencil, put dots through holes/notches F, G, H and I (see above illustration). Remove the mounting plate and draw lines extending through the points. This will give the location and size of the box cutout for the rear wall duct.

3Use a saw (saber or keyhole) to cut out the opening.

4Place the microwave in its upright position with the top of the unit facing up.

15

Back of

B1. PREPARING THE REAR WALL FOR OUTSIDE BACK EXHAUST Microwave

8Slide exhaust adaptor to one side and remove it.

Page 15
Image 15
GE Over the Range Microwave Oven manual B1. PREPARING THE REAR WALL FOR OUTSIDE BACK EXHAUST, Installation Instructions