Installation Instructions
C3. CHECK MICROWAVE ASSEMBLY
Exhaust Adaptor (absent on models shipped for recirculation exhaust)
Back of
Microwave
•Place the microwave in its upright position, with the top of the unit facing up.
•The microwave oven may be shipped assembled for top exhaust (adaptor installed) or for recirculation exhaust (adaptor absent).
•If the microwave was shipped for recirculation exhaust, skip to C5. If shipped for top exhaust, proceed with C4.
C4. ADAPTING MICROWAVE BLOWER FOR RECIRCULATION
1 Remove | Damper 2 Lift off the |
and save | blower plate |
screw that | and attached |
holds | adaptor from |
blower | the microwave. |
plate to |
|
microwave. | Back of |
| |
| Microwave |
3Slide exhaust adaptor to one side and remove it.
NOTE: The exhaust adaptor with damper is not needed for recirculating models. You may want to save them for possible future use.
4Remove and save the screw that holds the blower motor to the microwave.
Blower Plate
Back of
Microwave
Blower Motor
Screw
20
5Carefully pull out the blower unit. The wires will extend far enough to allow you to adjust the blower unit.
6Roll the blower unit 90° so that fan blade openings are facing toward the front of the microwave.
BEFORE: Fan Blade
Openings Facing Up
Roll
AFTER: Fan Blade
Openings Facing
Forward
NOTE: Make sure wires remain routed in the grooves of the motor frame.