Installation Instructions
2

Minimum Clearance Other Than Alcove or Closet Installation

Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear.
Consideration must be given to provide adequate clearance for installation and service.

2 GAS REQUIREMENTS

WARNING
• Installation must conform to local codes and
ordinances, or in their absence, the NATIONAL FUEL
GAS CODE, ANSI Z223.
• This gas dryer is equipped with a Valve & Burner
Assembly for use only with natural gas. Using
conversion kit WE25X0217, your local service
organization can convert this dryer for use with
propane (LP) gas. ALL CONVERSIONS MUST BE MADE BY
PROPERLY TRAINED AND QUALIFIED PERSONNEL AND
IN ACCORDANCE WITH LOCAL CODES AND ORDINANCE
REQUIREMENTS.
• The dryer must be disconnected from the gas supply
piping system during any pressure testing of that
system at a test pressure in excess of 0.5 PSI (3.4 KPa).
• The dryer must be isolated from the gas supply piping
system by closing the equipment shut-o valve during
any pressure testing of the gas supply piping of test
pressure equal to or less than 0.5 PSI (3.4 KPa).

GAS SUPPLY

• A 1/8-in.National Pipe Taper thread plugged tapping,
accessible for test gauge connection, must be installed
immediately upstream of the gas supply connection to
the dryer. Contact your local gas utility should you have
questions on the installation of the plugged tapping.
• Supply line is to be 1/2-in. rigid pipe and equipped with an
accessible shut-off within 6 ft. of, and in the same room
with the dryer.
•Use pipe thread sealer compound or Teon tape appropri-
ate for natural or LP gas.
• You must use with this dryer a exible metal connector
listed connector ANSI Z21.24 / CSA 6.10. The length of the
connect shall not exceed 3 ft.
• Connect exible metal connector to dryer and gas supply.
• Open shut-off valve.
INTERNAL DUCT
OPENING CHECK THAT EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY.
WALL
TILT THE DRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADS BY
PULLING AT THE SIDES
AND BREAKING THEM
AWAY FROM THE DRYER
LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND
THE LEGS.

1 PREPARING FOR INSTALLATION

OF NEW DRYER

TIP: Install your dryer before installing your washer.
This will allow better access when installing dryer
exhaust.

DISCONNECTING GAS

REMOVING LINT FROM WALL

EXHAUST OPENING

Remove and discard existing plastic or metal foil
transition duct and replace with UL listed transition
duct.
DISCONNECT AND DISCARD OLD
FLEXIBLE GAS CONNECTOR AND
OLD TRANSITION DUCTING
MATERIAL. REPLACE WITH NEW
CSA(AGA) APPROVED FLEXIBLE
GAS LINE CONNECTOR AND UL
APPROVED TRANSITION DUCT.
TURN GAS
SHUT-OFF VALVE
TO THE OFF
POSITION.
WARNING - NEVER REUSE OLD

FLEXIBLE CONNECTORS.

The use of old exible connectors can cause leaks and
personal injury. Always use new exible connectors
when installing gas appliances.
DRYER GAS SUPPLY CONNECTION
2"
2-5/8" 3/8" NPT MALE THREAD GAS SUPPLY
NOTE: Add to vertical dimension
the distance between cabinet
bottom to floor.