Tripp Lite PDUNV owner manual Owner’s Manual, Manual del propietario, Pdunv, Important Warnings

Models: PDUNV

1 2
Download 2 pages 60.02 Kb
Page 1
Image 1
Warranty

Warranty

 

 

 

 

chance

 

 

 

 

 

 

Registration

a

 

product!

 

 

 

 

 

for

 

 

 

 

 

.com/warranty

 

 

 

today

 

Lite

 

 

 

online

Tripp

 

 

 

 

Registerwin

 

FREE

 

 

 

 

 

 

a

.tripplite

 

 

 

 

 

to

www

 

 

 

 

 

 

Owner’s Manual

PDUNV

Universal Rackmount

Power Distribution Unit (PDU)1111 W. 35th Street • Chicago, IL 60609 USA (773) 869-1234 • www.tripplite.com

Important Safety Instructions

Installation (continued)

SAVE THESE INSTRUCTIONS

This manual contains instructions and warnings that should be followed during the installation, operation, and storage of this product. Failure to heed these instructions and warnings will void the product warranty.

Important Warnings

The PDU provides convenient multiple outlets, but it DOES NOT provide surge or line noise protection for connected equipment.

The PDU is designed for indoor use only in a controlled environment away from excess moisture, temperature extremes, conductive contaminants, dust or direct sunlight.

Do not connect the PDU to an ungrounded outlet or to extension cords or adapters that eliminate the connection to ground.

The power requirement for each piece of equipment connected to the PDU must not exceed the individual outlet’s load rating.

The total power requirement for equipment connected to the PDU must not exceed the maximum load rating for the PDU.

Do not drill into or attempt to open any part of the PDU housing. There are no user-serviceable parts inside.

Do not attempt to modify the PDU, including the input plugs and power cables.

Do not attempt to use the PDU if any part of it becomes damaged.

Do not attempt to mount the PDU to an insecure or unstable surface.

Never attempt to install electrical equipment during a thunderstorm.

Installation

Step 3: Connect Equipment to PDU. Connect equipment to the PDU with user-supplied IEC-320 interconnection cords. Be careful not to exceed the load rating for each outlet nor the total load rating for the PDU. Note: Interconnection cords (IEC-320-C13 to IEC- 320-C14) are available from Tripp Lite. Call 773-869-1234 (Part # P004-006).

3

Step 4: Optional Installation (Not Shown). The input power

 

cord’s IEC-320-C20 connector and the IEC-320-C14 adapter can

each connect to user-supplied power cords with plugs appropriate for the installation site’s utility outlets. This capability is useful for connecting the PDU to various international outlet types.

Features

 

 

 

 

 

 

 

 

INPUT PLUG ADAPTERS

 

 

D

E

F

G

H

I

A

B

 

 

 

 

 

 

C

 

 

 

 

 

A

IEC-320-C19 Outlets

 

 

D

 

 

NEMA 5-15P connects to NEMA 5-15R outlet.

 

 

 

 

 

 

 

NEMA 5-20P connects to NEMA 5-20R outlet.

B

IEC-320-C13 Outlets

 

 

E

 

 

 

 

NEMA L5-20P connects to NEMA L5-20R outlet.

C

Circuit Breaker: If the current drawn by the

F

equipment connected to the PDU exceeds the

 

NEMAL6-20P connects to NEMAL6-20R outlet.

G

Maximum Load Rating for longer than a few

 

IEC-320-C14 connects to user-supplied power

H

seconds, the circuit breaker will activate and interrupt

cord with IEC-320-C13 or to a UPS/power supply.

AC power to prevent possible damage. When the

 

 

 

 

I

IEC-320-C20 connects to user-supplied power

circuit breaker activates, its plunger

will pop

up.

cord with IEC-320-C19, to an input adapter or to a

Disconnect excess equipment from

the PDU

and

 

 

 

 

 

B

 

B

 

C

 

A

 

A

1-1

1-2

allow the breaker to cool one minute before depressing the plunger to reset the breaker.

UPS/power supply.

 

 

C

B

 

 

 

B

C

A

C

 

 

 

1-3

 

 

A

 

1-4

 

Step 1: Determine Installation Configuration. The PDU supports four primary installation configurations: 1U Rack, 0U Rack, Wall and Under-Counter. Choose a configuration and follow the installation instructions in the appropriate section of Step 1 before proceeding to Step 2.

Note: Regardless of installation configuration, the user must determine the fitness of hardware and procedures before mounting. The PDU and included hardware are designed for common rack and rack enclosure types and may not be appropriate for all applications. Exact mounting configurations may vary.

Step 1-1: 1U Rack Installation. Attach the PDU to the rack by inserting four user-supplied screws (A) through the PDU mounting brackets (B) and into the mounting holes of the rack rail as shown.

Step 1-2: 0U Rack Installation. Part 1: Remove the screws (C) attaching the mounting brackets to the PDU, change the orientation of the brackets as shown and reattach the brackets. Use only the screws supplied by the manufacturer or their exact equivalent (#6-32, 1/4” flat head). Part 2: Attach the PDU vertically by inserting two or more user-supplied screws (A) through the PDU mounting brackets (B) and into mounting points in the rack or rack enclosure.

Step 1-3: Wall Installation. After repeating Part 1 above, attach the PDU to a stable mounting surface by inserting two or more user-supplied screws (A) through the PDU mounting brackets (B) and into secure mounting points on the mounting surface.

Step 1-4: Under-Counter Installation. After repeating Part 1 above, attach the PDU to a stable mounting surface by inserting four user-supplied screws (A) through the PDU mounting brackets (B) and into secure mounting points on the mounting surface.

FStep 2: Connect PDU to Grounded Outlet. The PDU includes several plug

adapters which allow the PDU to connect to various outlet types. After choosing the appropriate plug adapter for the required application, insert the IEC-320-C19 connector (D) of the adapter into the IEC-320-C20 connector (E) of the input cable.

DSecure the connection with the Cord Retention Bracket (F) by using the included

E

2bolts to fasten the two halves of the bracket around the connection as shown. Insert the plug directly into a properly grounded AC outlet that does not share a circuit with a heavy electrical load (such as an air conditioner or refrigerator). Caution: The Line (L1) conductor includes

an over-current protective device for safety. To avoid the risk of electric shock, ensure that the Neutral (L2) conductor has been identified before connecting the PDU.

Limited Lifetime Warranty

Seller warrants this product, if used in accordance with all applicable instructions, to be free from original defects in material and workmanship for its lifetime. If the product should prove defective in material or workmanship within that period, Seller will repair or replace the product, at its sole discretion. Service under this Warranty can only be obtained by Buyer delivering or shipping the product (with all shipping or delivery charges prepaid) to: Tripp Lite, 1111 W. 35th Street, Chicago, IL 60609. Seller will pay return shipping charges. Call Tripp Lite at (773) 869-1234 before sending any equipment back for repair.

THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT, MISUSE, ABUSE OR NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANTABILITY OR FITNESS, ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET FORTH ABOVE; THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES. (Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights, and you may have other rights which vary from jurisdiction to jurisdiction).

WARNING: The individual user should take care to determine prior to use whether this device is suitable, adequate or safe for the use intended. Since individual applications are subject to great variation, the manufacturer makes no representation or warranty as to the suitability or fitness of these devices for any specific application.

The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.

WARRANTY REGISTRATION

Visit www.tripplite.com/warranty today to register the warranty for your new Tripp Lite product. You'll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product!*

* No purchase necessary. Void where prohibited. Some restrictions apply. See website for details.

Regulatory Compliance Identification Numbers

For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned a unique series number. The series number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to the series number. The series number should not be confused with the marking name or model number of the product.

This product designed and engineered in the USA.

Copyright © 2006 Tripp Lite. All rights reserved.

Manual del propietario

PDUNV

Montaje en bastidor

Unidad universal de distribución de potencia (PDU)

Instrucciones de seguridad importantes

GUARDE ESTAS INSTRUCCIONES

Este manual contiene instrucciones y advertencias que deben seguirse durante la instalación, operación y almacenamiento de este producto. De no seguirlas, se anulará la garantía del producto.

Advertencias importantes

La PDU proporciona cómodas salidas múltiples, pero NO proporciona protección contra sobretensión o ruido en la línea al equipo conectado.

La PDU está diseñada sólo para empleo en interiores en un ambiente controlado, lejos del exceso de humedad, temperaturas extremas, contaminantes conductores, polvo o luz solar directa.

No conecte la PDU a una salida sin conexión a tierra ni a cables de extensión o adaptadores que eliminen la conexión a tierra.

El requisito de potencia de cada equipo conectado a la PDU no debe exceder la capacidad de carga individual de la salida.

El requisito de potencia total para el equipo conectado la PDU no debe exceder la máxima capacidad de carga para la PDU.

No taladre ni trate de abrir ninguna parte de la cubierta de la PDU. No hay partes en su interior que requieran mantenimiento por parte del usuario.

No intente modificar la PDU, incluyendo los enchufes de entrada y los cables de alimentación.

No intente usar la PDU si alguno de sus componentes está dañado.

No intente montar la PDU en una superficie insegura o inestable.

Nunca intente instalar equipos eléctricos durante una tormenta eléctrica.

 

1111 W. 35th Street • Chicago, IL 60609 USA

 

 

 

 

 

(773) 869-1234 • www.tripplite.com

 

 

 

Instalación

 

 

 

 

 

B

 

 

 

 

 

 

 

B

 

C

A

 

 

 

 

 

 

A

 

 

 

 

1-1

 

1-2

 

 

 

 

 

C

B

 

C

B

C

A

 

 

 

1-3

 

 

 

A

 

 

1-4

 

 

 

Paso 1: Determine la configuración de la instalación. La PDU soporta cuatro configuraciones básicas de

instalación: Bastidor de 1U, bastidor de 0U, de pared y debajo de mostrador. Elija una configuración y siga las instrucciones de instalación en la sección apropiada del Paso 1 antes de continuar al Paso 2. Nota: Independientemente de la configuración, el usuario debe determinar la idoneidad de los materiales y accesorios así como de los procedimientos antes del montaje. La PDU y el material incluido están diseñados para racks (bastidores) y cajas de rack (bastidor) comunes, y pueden no ser apropiados para todas las aplicaciones.

Paso 1-1: Instalación en bastidor de 1U. Fije la PDU al bastidor insertando cuatro tornillos suministrados por el usuario (A) a través de los soportes de montaje (B) de la PDU en los agujeros de montaje del riel del bastidor como se muestra.

Paso 1-2: Instalación en bastidor de 0U. Parte 1: Retire los tornillos (C) que fijan los soportes de montaje a la PDU, cambie la orientación de los soportes como se muestra y fíjelos nuevamente. Use solo los tornillos incluidos o sus equivalentes exactos (#6-32, 1/4" de cabeza plana). Parte 2: Fije la PDU verticalmente insertando dos o más tornillos suministrados por el usuario (A) a través de los soportes de montaje (B) de la PDU en los puntos de montaje en el bastidor o la caja del bastidor.

Page 1
Image 1
Tripp Lite PDUNV owner manual Owner’s Manual, Manual del propietario, Pdunv, Important Safety Instructions, Installation