GE RAK148P1, RAK164P1 Starting the thermostat, Testing the thermostat, Cool Test

Models: RAK164P1 RAK148P1

1 24
Download 24 pages 38.62 Kb
Page 11
Image 11
Starting the thermostat.

Starting the thermostat.

Testing the thermostat.CAUTION! Do not use air conditioning when the outdoor temperature is below 50 degrees. This can damage your air conditioning system and cause personal injuries.

1.Move the Fan Auto/On switch to the Auto position. On position runs indoor fan continuously.

2.Move the Function switch to Cool or Heat, depending on the season.

OFF AM

Time

Room Temperature

OFF Indicator

Testing the thermostat.

Once the thermostat is installed, it should be thoroughly tested.

Once the thermostat is installed, it should be thoroughly tested.CAUTION! Do not use air conditioning when the outdoor temperature is below 50 degrees. This can damage your air conditioning system and cause personal injuries.

Note: Before testing the thermostat, move the Fan Auto/On switch to the Auto position.

Cool Test

1.Slide Function switch to Cool position. Cool mode screen is displayed.

2.Adjust set temperature so it is 5 degrees below room temperature.

COOL

AM

3.Air conditioning should come on within a few seconds.

4.Adjust the set temperature so it is 2 degrees above the room temperature and the A/C should turn off. Note: There is a 3 minute time delay and a 3 minute minimum run time for the compressor when it turns on/off. (On some models, the fan may also have a 3 minute minimum run time/off time delay.)

11

Page 11
Image 11
GE RAK148P1, RAK164P1 installation instructions Starting the thermostat, Testing the thermostat, Cool Test