GE RAK148P1, RAK164P1 installation instructions Room temperature offset +9F to -9F +5C to -5C

Models: RAK164P1 RAK148P1

1 24
Download 24 pages 38.62 Kb
Page 9
Image 9
6. Room temperature offset (+9°F to –9°F) (+5°C to –5°C)

3.Temperature Differential—Stage 2—(RAK148P1 only) (1–9°F) (1–5°C)—Set the number of degrees between when stage 1 turns on and stage 2 turns on.

Press the

<

or

>

button to set differential value.

Press the Hold button to advance to the next screen.

4. Minimum Cool Setpoint (60, 64, 66, 68, 70, 72, 74, 76°F) (15, 17, 19, 20, 21, 22, 23, 24°C)

Adjust to control the minimum Cool set temperature allowed.

Press the

<

or

>

button to select.

Press the Hold button to advance to the next screen.

5. Maximum Heat Setpoint (65, 70, 72, 74, 76, 78, 80, 85°F) (18, 21, 22, 23, 24, 26, 27, 29°C)

Adjust to control the maximum Heat set temperature allowed.

Press the

<

or

>

button to select.

Press the Hold button to advance to the next screen.

6. Room temperature offset (+9°F to –9°F) (+5°C to –5°C)

Adjust to calibrate displayed room

temperature to match actual room temperature.

Press the

<

or

>

button to select.

Press the Hold button to advance to the next screen.

Move the Function switch to Heat or Cool position to lock the settings into memory.

9

Page 9
Image 9
GE RAK148P1, RAK164P1 installation instructions Room temperature offset +9F to -9F +5C to -5C