3.6Motor Wiring
3.6.1
When initially connecting to the power source, be certain that the motor volt- age connections and available line voltage are the same. Connect electrical wires as shown on the motor wiring diagram located on the motor name- plate, electrical junction box, junction box cover, or wiring tag. Be sure your pump is electrically grounded at the junction box on the motor.
3.6.2
The wiring diagram located on the motor nameplate, electrical junction box, junction box cover, or wiring tag should be used to correctly wire the motor according to the line voltage available. Be sure your pump is electrically grounded at the junction box on the motor.
CAUTION: The 500X, 1000X and 1800X motor adapter pumps have a threaded motor shaft. Reverse operation can damage the motor shaft, pump shaft, or centrifugal stages.
Before Starting
STEPS
1.Prime pump before applying power to avoid damage to the pump.
2.Apply power for ONE SECOND MAXIMUM to check the direction of motor shaft rotation. The motor shaft should turn in a clockwise direc- tion as viewed from the motor end. The direction of rotation for three- phase motors may be reversed by interchanging any two (2) leads (Figure 3.3, Changing Motor Rotation).
STEPS
A.Start the pump and note the pressure and flow rate developed at the pump discharge.
B.Stop the pump and interchange any of the two leads.
C.Start the pump again and recheck the flow rate and pressure.
9