2.0TONKAFLO SPECIFICATIONS
The Tonkaflo pumps covered in this instruction manual are the lower capacity SS500, SS1000, and SS1800 Series pumps. These pumps cover a flow range of 1.5 - 18 gpm (0.34 - 4.1 m3/h) with single unit pressure up to 700 psig (48.3 barg). The capacity and discharge pressure can be increased by operating pumps in parallel or series, respectively. There is no maximum limit on capacity when operating Tonkaflo pumps in parallel. When operating pumps in series, the maximum rated discharge is 750 psig (51.7 barg) with standard pumps, and 1000 psig (69 barg) with optional
2.1Capacities
Table 2.1
Capacities
SS | 2900 rpm | 3500 rpm |
| Maximum |
50 Hertz | 60 Hertz |
| ||
Series | Minimum - Maximum | Minimum - Maximum |
| Efficiency |
|
|
|
|
|
500 | 1 - 6 gpm | 1.5 - 7 gpm |
| 40% |
| (0.23 - 1.4 m3/h) | (0.34 - 1.6 m3/h) |
|
|
|
|
|
|
|
1000 | 3.3 - 11 gpm | 4 - 13 gpm |
| 49% |
| (0.75 - 2.5 m3/h) | (0.91 - 30. m3/h) |
|
|
|
|
|
|
|
1800 | 4 - 17.5 gpm | 5 - 21 gpm |
| 57% |
| (0.91 - 4.0 m3/h) | (1.14 - 4.8 m3/h) |
|
|
|
|
|
|
|
NOTE: There must be adequate flow at all times through the pump to prevent excessive heat
2