–GE Monogram 48" Dual Fuel Professional Range with 6 Burners and Griddle
Electrical Requirements
Ranges must be supplied with 208/240V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a circuit breaker or
Locate gas and electric as shown
8" | 4" | 8" |
|
| |
12" |
| 16" |
|
| |
4" |
|
|
|
| |
|
|
|
| ||
Gas |
| Electric |
| ||
|
|
| |||
Supply |
| Supply | |||
|
| 48" |
|
|
Gas Supply
•Natural gas models are designed to operate at 5" water column pressure. A regulator is required at the natural gas source to provide maximum of 7" water pressure to the range regulator.
•The liquid propane models are designed to operate at 10" water column pressure. A regulator is required at the LP source to provide maximum of 14" water pressure to the range regulator.
Optional Backsplash Accessories
The range requires a 12" minimum clearance to a vertical combustible surface at the rear. A backsplash is required for installations with less than 12" clearance. The following backsplash accessories are available, or a custom,
Backsplashes: Order one with a
Backsplash with Warming Shelf
All Monogram Professional
If you choose to install this range with a
Side View with a Backsplash
12" Min. to Combustibles or 0" Min. to Combustibles with 12" or 22" Backsplash
36" Min.
to Combustibles
Backguard
0" Clearance
|
| Listed by |
|
| Underwriters |
| R | Laboratories |
|
| |
| For answers to your Monogram,® GE Profile™ or | |
| GE® appliance questions, visit our website at | |
| GEAppliances.com or call GE Answer Center® | |
Specification Revised 10/05 | service, 800.626.2000. |