GE ZIDI240 Design Guide, The Installation Space, Product Clearances, Side-By-Sideinstallations

Models: ZIDS240 ZIDI240

1 8
Download 8 pages 47.09 Kb
Page 4
Image 4
Design Guide

Design Guide

FOR MODEL ZIDS240 WITH STAINLESS STEEL DRAWERS AND HANDLES

THE INSTALLATION SPACE

PRODUCT CLEARANCES

IMPORTANT: Double-Drawer Refrigerators are designed to be built-in only. They cannot be used free-standing.

When installed in a corner:

Countertop

Double-Drawer

Locate

Outlet

10-1/2"

34-1/2"-35" 9" Max. THE INSTALLATION SPACE

24"

22" min.

1-1/2"

PRODUCT CLEARANCES 23-3/4" Min. The cutout depth should be 24″34-1/4"to 34-3/4"

NOTE:

25-7/8"

34-1/4"

Handle and

Including

to 34-3/4"

handle standoff

Handles

 

depth is 2-1/8

 

 

 

 

23-3/4"

The cutout depth should be 24

NOTE: The unit is designed to be flush with the surrounding cabinets.

Additional Specifications

A 120 volt 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded 3-prong electrical receptacle recessed into the back wall as shown. Electrical must be located on rear wall as shown. NOTE: GFCI (ground fault circuit interrupter) is not recommended.

Clearance for Door

Opening 2-1/2" min.

Allow 2-1⁄2min. clearance between Double-Drawer and adjacent cabinet, wall or other appliances. Allow 22min. clearance from the front for drawer opening.

NOTE: Clearances are based on the noted 2-1⁄8handle standoff depth.

Test the drawer openings. Carefully open and close the drawers. The drawers should not rub or catch on adjacent cabinetry. Notify the installer if the drawers make contact with cabinetry.

Choose the location:

These products may be closed in on the top and three sides as long as the front is unobstructed for air circulation and proper access to the drawers.

Do not install these products where the temperature will go below 55°F (13°C) or above 90°F (32°C).

These products are not designed to be stacked one over the other.

SIDE-BY-SIDE INSTALLATIONS –

Stainless Steel Models Only

For a complete refreshment center, install a Double-Drawer

 

 

 

 

 

 

 

 

 

 

Locate

 

 

 

 

 

 

 

 

 

 

 

Outlet

Refrigerator beside a Beverage Center, Wine Chiller/

 

 

 

 

 

 

 

 

 

 

 

 

 

10-1/2"

 

14"

 

10-1/2" 24"

Wine Reserve, Fresh-Food Refrigerator or Bar Refrigerator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

with Icemaker.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34-1/2"-35"

9"

 

9"

 

 

 

 

 

 

 

• A side-by-side installation requires at least a 47-1/2wide

 

 

 

 

15"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/2"

 

 

opening. No trim kits required.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

47-1/2" Min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Products must operate from separate, properly grounded receptacles.