Installation

WARNING:

TEST FOR LEAKS

A complete gas tightness check must be performed at the installation site.

CAUTION:

To prevent fire or explosion hazard, DO NOT use or permit sources of ignition in the area while performing a leak test . Perform leak test outdoors only. Never perform a leak test with fire or flame. DO NOT SMOKE WHILE PERFORMING THE LEAK TEST.

Use an approved non-corrosive leak detection solution or create a soapy solution of equal parts mild dishwashing detergent and water.

Check to be sure all controls are in the OFF position.

Turn on the fuel supply. For natural gas, turn manual shut-off valve handle 1/4 turn to align with gas flow. For LP, turn cylinder valve knob counterclockwise one full rotation.

Apply liquid leak detector generously on all connections and fittings. See illustrations.

If growing bubbles appear on any connection point, IMMEDIATELY turn off the gas supply.

To stop a gas leak:

Turn off the fuel supply.

Turn on control knobs to release pressure. Turn controls OFF.

Wash off soapy solution and towel dry.

Tighten the loose joint and perform a new leak test .

Natural Gas Leak

Test Points

LP Gas Leak

Test Points

LP Gas Leak Test Points

With Cooktop

To Manifold

of Grill

3/8"

To Cooktop

Flare Tee

 

From Regulated

LP Tank

18

Page 18
Image 18
GE Monogram Professional Outdoor Grills and Cooktop installation instructions Test for Leaks, To stop a gas leak