5 CHANGE GRIDDLE ORIFICE (if present)

Installation Instructions for Gas Conversion

5 CHANGE GRIDDLE ORIFICE (if present)

Locate the 3/4” long Griddle orifice.

Select for your gas type. LP.047, NAT.076

A. Lift off

the griddle flue

 

cover. Remove

Griddle Flue Cover

the 2 inside

A

clamping

screws.

 

6 ADJUST BURNER FLAMES

Normally, burners do not need further adjustment. Make adjustments only when necessary.

A. Turn on the gas. Plug in electrical cord.

B. Turn all burners on highest setting and check

the flames. They should be blue in color. When

using LP gas, the flames may have some yellow

tipping at the ends of the flame. Foreign particles

B. Use a pad or

 

 

piece of

 

 

carton to

 

 

protect

Leveling Screws

the adjacent

surface. Slide

 

 

the griddle

Clamping Screws

toward

the rear

 

 

and out of

 

B

the hold-down tabs along

the bottom.

 

 

6 ADJUST BURNER FLAMES NOTE: Remove

the 2 screws positioned on the inside only. Do not remove the outermost screws—they are for leveling.

in the gas line may cause an orange flame at first,

but this will soon disappear.

C. Turn the burner knob to “LO” while observing the

flame.

Adjust the setting of the upper row of flames using the valve bypass screw as follows:

Adjustments must be made with two other burners in operation on a medium setting. This prevents the upper row of flames from being set too low, resulting in the flame being extinguished when other burners are turned on.

C.CAREFULLY lift and hold the griddle. A thermostat capillary is routed through a clip. Gently lift the griddle to one side and slip the capillary out of the clip.

D.Lay the griddle

on the padded surface. Do not disconnect or pull on the capillary.

E.Remove the 2 burner hold-down screws

at the rear of the burner.

Pull the burner straight back toward the rear and out of the gas inlet.

C

Capillary

D

D.To adjust the flame, remove the knobs. Insert a small flat-blade screwdriver into the hole in the center

of the valve stem to engage screw.

If the flames are too small or flutter, turn the screw counterclockwise.

F.Use a 1/2" deep well socketManual background

to remove and replace the orifice.

E

Back of Range

F

Front of Range

Reverse these steps to re-assemble the griddle. Push excess capillary back into the entry hole. Route the thermostat capillary so it is held by the clip. Place the unused orifice in the holder for possible future use.

If the flames are too large, turn the screw clockwise.

E.Make the adjustment by slowly turning the screw until flame appearance is correct.

Once the conversion is complete and checked, fill out the conversion label and affix the label near the rating label. For ranges, place the label beneath the control panel. For rangetops, place the label on the bottom of the unit.

17

Page 17
Image 17
GE Monogram Professional Rangetop installation instructions CHANGE GRIDDLE ORIFICE if present, Adjust Burner Flames