GE Monogram ZDIW50 installation instructions Vacation and Moving, To shut down the icemaker

Models: ZDIW50

1 44
Download 44 pages 32.03 Kb
Page 15
Image 15
Vacation and Moving

Vacation and Moving

WARNING: Make sure the icemaker is disconnected from the main power supply before removing the lower access panel. Failure to do so could result in electric shock or personal injury.

To shut down the icemaker:

1.Disconnect the electrical power supply to the icemaker and turn the Cycle Control Knob to “OFF.”

2.Remove all ice from the storage bin.

3.Shut off the water supply.

4.Remove the screw from the top of the lower access panel and the two screws from the grille area of the lower access panel, then remove the panel. Pull forward at the bottom, then down.

5.Disconnect the inlet and outlet lines to the water valve. Allow these lines to drain and then reconnect to the valve.

6.Replace the lower access panel and screws. The top of the access panel needs to be secured under the two metal tabs before replacing the screws.

7.Remove water from the drain lines and drain water pan.

8.Before using again, clean the icemaker and storage bin.

NOTE: All components of the icemaker are permanently lubricated at the factory. They should not require any additional oiling throughout the normal life of the machine.

NORMAL

 

ON

THIN

THICK OFF

CLEAN

ICE

CYCLE

Lower

Screw

Access

 

Panel

 

Grille

 

Area

Screws

Outlet

Inlet

 

Water

Pan

15