GE Monogram ZSC2201, ZSC2200 Installation Preparation, Advertencia, Electrical Requirements

Models: PSB9240DF PSB9240SF ZSC2202 ZSC2200 ZSC2201

1 32
Download 32 pages 41.15 Kb
Page 5
Image 5
Installation Preparation

Installation Preparation

ELECTRICAL REQUIREMENTS

Single Speedcook Installation

Product rating is 120/208 or 120/240 volt, 60 Hz,

30 amps. This product must be connected to a supply circuit of the proper voltage and frequency and protected by a time delay fuse or circuit breaker. Power should be supplied from a separate, dedicated 30-ampere branch circuit. Wire size must conform to the requirements of the National Electrical Code or the prevailing local code.

Combined Speedcook and Wall Oven Installation

When installed in combination with a GE/Monogram single wall oven, use separate electrical junction boxes.

Refer to single oven installation instructions for electrical requirements of that product.

These connections must be made by a qualified electrician. All electrical connections must meet National Electrical Code or prevailing local codes.

Combined Speedcook and Warming Drawer Installation

When installing the Speedcook oven over a GE or Monogram electric warming drawer, a separate 120V, 60Hz, properly grounded receptacle must be installed. See instructions packed with the warming drawer.

ELECTRICAL REQUIREMENTSWARNING

‡The electrical power to the oven branch circuit must be shut off while line connections are being made.

‡Use copper wiring only.

‡Electrical ground is required on this appliance. The free end of the green wire (ground wire) must be connected to a suitable ground.

This wire must remain grounded to the oven.

‡If cold water pipe is interrupted by plastic, non-metallic gaskets, union connections or other insulating materials, DO NOT use for grounding.

‡DO NOT ground to a gas pipe.

‡DO NOT have a fuse in the NEUTRAL or GROUNDING circuit. A fuse in the NEUTRAL or GROUNDING circuit could result in an electrical shock.

‡Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded.

Failure to follow these instructions could result in serious injury or death.

Single Speedcook InstallationADVERTENCIA

‡El encendido eléctrico al circuito paralelo deberá estar apagado mientras se realizan las conexiones de línea.

‡Use conductores de cobre únicamente.

‡Este electrodoméstico requiere que se realice una conexión a tierra. El extremo libre del cable verde (cable a tierra) debe estar conectado a una conexión a tierra adecuada. Este cable debe permanecer conectado a la conexión a tierra del horno.

‡Si la tubería de agua fría presenta interrupciones por plásticos, juntas, conexiones de uniones u otros materiales aislantes, NO use la misma como conexión a tierra.

‡NO se debe conectar a tierra en una tubería de suministro de gas.

REQUISITOS ELÉCTRICOS (Cont)

‡NO posee un fusible en el circuito neutro o de conexión a tierra. Un fusible en el circuito neutro o de conexión a tierra podría ocasionar una descarga eléctrica.

‡Consulte a un electricista calificado o personal del servicio si tiene dudas de que el electrodoméstico se encuentre conectado a tierra apropiadamente.

Si no se siguen estas instrucciones, se podrán producir lesiones graves o la muerte.

INSTALL JUNCTION BOX

The conduit is located at the top right on the back of the oven.

Locate and install the junction box within reach of the oven conduit.

‡ Through the left or right sides of the cabinet wall and into adjacent cabinet.

‡ Or, through the cutout floor.

‡ Or, in the upper cabinet.

Cutout

Height

5

Page 5
Image 5