Preparation WITHOUT an Accessory Storage Drawer

Installation Preparation

Preparation WITHOUT an Accessory Storage Drawer

PREPARE THE OPENING

The Advantium 240V can be installed in combination with other GE/Monogram appliances. Always follow each product’s Installation

PREPARE THE OPENING (CONT.)

Installation over a GE/Monogram Warming Drawer:

Instructions to complete the installation.

Single Advantium 240V Installation:

Order a 30” wide single oven cabinet or cut the opening in a wall to the dimensions shown.

30” PREPARE THE OPENING

23-1/2”

Construct Solid Bottom Min. 3/8” Plywood Supported by 2x4 or 2x2

30”

17-1/2”

36-3/4”

23-1/2”

PREPARE THE OPENING (CONT.)Installation over a GE/Monogram Warming Drawer: 25-1/4” Single Advantium 240V Installation:

Construct Base Min. 3/8” Plywood Supported by 2x4 or

17-1/2”

36-3/4”

Min.

Manual background 25-1/4”

Runners all

Four Sides

2” Min.

Manual background (3” recommended)

Per warming drawer requirement

Min.

2x2 Runners all Four Sides

NOTE: Additional clearances between the cutouts may be required. Check to be sure the oven supports above the Warming Drawer location do not obstruct the required interior depth and height. See Warming Drawer installation instructions for details.

‡$OZD\VPDLQWDLQµPLQLPXPKHLJKWIURP the floor to the cutout in any single or combined installation.

‡$OORZµFDVHWULPRYHUODSRQWKHVLGHVDQG 7/8” overlap on the bottom of the opening for all models. Allow 1-1/4” case trim overlap on the top for models PSB9120 and 3/4” overlap on the top for models ZSC2200, ZSC2200, ZSC2201 and ZSC2202.

‡2YHQRYHUODSVZLOOFRQFHDOFXWHGJHVRQDOOVLGHV of the opening.

When installed over a single oven or a warming drawer, allow at least 2” between the two openings. This separation will provide clearance for bottom overlap of the Advantium 240V and the other appliance overlaps.

Construct a solid oven floor of 3/8” min. thick plywood supported by 2 x 4 or 2 x 2 runners on all sides.

‡7KHVXSSRUWPXVWEHOHYHODQGULJLGO\PRXQWHG flush with the bottom edge of the cutout.