GE Monogram PSB9240SF Installation Preparation Preparation WITH an Accessory Storage Drawer

Models: PSB9240DF PSB9240SF ZSC2202 ZSC2200 ZSC2201

1 32
Download 32 pages 41.15 Kb
Page 8
Image 8
Installation Preparation

Installation Preparation

Preparation WITH an Accessory Storage Drawer

NOTE: MODEL ZSC2202 CANNOT BE INSTALLED WITH AN ACCESSORY STORAGE DRAWER. SEE INSTALLATION PREPARATION WITHOUT AN ACCESSORY STORAGE DRAWER FOR THIS MODEL.

PREPARE THE OPENING

The Advantium 240V can be installed in combination with other GE/Monogram appliances. Always follow each product’s Installation Instructions to complete the installation.

Single Advantium 240V Installation:

Order a 30” wide single oven cabinet or cut the opening in a wall to the dimensions shown.

PREPARE THE OPENING (CONT.)

Single Advantium 240V Installation (cont.)

When installed over a single oven or a warming drawer, allow at least 2” between the two openings. This separation will provide clearance for bottom overlap of the Advantium 240V and the other appliance overlaps.

Construct a solid oven floor of 3/8” min. thick plywood

30”

23-1/2”

25-1/4” Single Advantium 240V Installation (cont.) Min.* Manual background

supported by 2 x 4 or 2 x 2 runners on all sides.

‡7KHVXSSRUWPXVWEHOHYHODQGULJLGO\PRXQWHG flush with the bottom edge of the cutout.

Installation over a GE/Monogram Warming Drawer:

21”

36-3/4”

Min.

Construct Base Min. 3/8” Plywood Supported by 2x4 or 2x2 Runners all Four Sides

30”Manual background

21”

23-1/2”

25-1/4” Manual backgroundManual background Min.*

Construct * Solid Bottom Min. 3/8” Plywood Supported

by 2x4 or 2x2 Runners all Four Sides

2” Min.

Manual background (3” recommended)

Per warming drawer requirement

*For existing cutouts, a maximum width of 28-1/2” is acceptable. If the opening is slightly wider, secure a furring strip on each side of the cutout for securing the oven.

‡$OZD\VPDLQWDLQµPLQLPXPKHLJKWIURP the floor to the cutout in any single or combined installation.

‡Allow 3/4” to 2-1/8” case trim overlap on the sides and 7/8” overlap on the bottom of the opening for all models. The amount of overlap on the sides depends on the actual cutout width. Allow 1-1/4” case trim overlap on the top for model PSB9120 and 3/4” overlap on the top for models ZSC2200, ZSC2200, ZSC2201 and ZSC2202.

‡2YHQRYHUODSVZLOOFRQFHDOFXWHGJHVRQDOOVLGHV of the opening.

36-3/4”

Min.

For existing cutouts, a maximum width of 28-1/2” is acceptable. If the opening is slightly wider, secure a furring strip on each side of the cutout for securing the oven.

NOTE: Additional clearances between the cutouts may be required. Check to be sure the oven supports above the Warming Drawer location do not obstruct the required interior depth and height. See Warming Drawer installation instructions for details.

8

Page 8
Image 8
GE Monogram PSB9240SF, ZSC2201 Installation Preparation Preparation WITH an Accessory Storage Drawer, Prepare The Opening