Installation Preparation
Preparation WITH an Accessory Storage Drawer
NOTE: MODEL ZSC2202 CANNOT BE INSTALLED WITH AN ACCESSORY STORAGE DRAWER. SEE INSTALLATION PREPARATION WITHOUT AN ACCESSORY STORAGE DRAWER FOR THIS MODEL.
PREPARE THE OPENING
The Advantium 240V can be installed in combination with other GE/Monogram appliances. Always follow each product’s Installation Instructions to complete the installation.
Single Advantium 240V Installation:
Order a 30” wide single oven cabinet or cut the opening in a wall to the dimensions shown.
PREPARE THE OPENING (CONT.)
Single Advantium 240V Installation (cont.)
When installed over a single oven or a warming drawer, allow at least 2” between the two openings. This separation will provide clearance for bottom overlap of the Advantium 240V and the other appliance overlaps.
Construct a solid oven floor of 3/8” min. thick plywood
30”
supported by 2 x 4 or 2 x 2 runners on all sides.
7KHVXSSRUWPXVWEHOHYHODQGULJLGO\PRXQWHG flush with the bottom edge of the cutout.
Installation over a GE/Monogram Warming Drawer:
21”
Min.
Construct Base Min. 3/8” Plywood Supported by 2x4 or 2x2 Runners all Four Sides
30”
21”
Construct * Solid Bottom Min. 3/8” Plywood Supported
by 2x4 or 2x2 Runners all Four Sides
2” Min.
(3” recommended)
Per warming drawer requirement
*For existing cutouts, a maximum width of
$OZD\VPDLQWDLQµPLQLPXPKHLJKWIURP the floor to the cutout in any single or combined installation.
Allow 3/4” to
2YHQRYHUODSVZLOOFRQFHDOFXWHGJHVRQDOOVLGHV of the opening.
Min.
For existing cutouts, a maximum width of
NOTE: Additional clearances between the cutouts may be required. Check to be sure the oven supports above the Warming Drawer location do not obstruct the required interior depth and height. See Warming Drawer installation instructions for details.
8