Generac 004451 ,004582 Operation, Know The Generator, 1512, Control Panel, Generator Controls

Models: 004451, 004582 004451 ,004582

1 39
Download 39 pages 37.64 Kb
Page 8
Image 8
Section 2 – Operation

Section 2 – Operation

Commercial-Industrial-Residential Portable Generator System

OPERATION

2.1 KNOW THE GENERATOR

Read the Owner’s Manual and Safety Rules before operating this generator.

Compare the generator to this illustration to become familiarized with the locations of various controls and adjustments. Save this manual for future reference.

Figure 4 - Control Panel

1)12 Volt DC, 10 Amp Receptacle – This receptacle allows the capability to recharge a 12 volt DC storage battery with provided battery charge cables.

2)120 Volt AC, 20 Amp, Duplex Receptacle – Supplies electrical power for the operation of 120 Volt AC, 20 Amp, single-phase, 60 Hz electrical lighting, appliance, tool and motor loads.

3)120 Volt AC, 20A Duplex GFCI Receptacle – Supplies ground fault protected electrical power for operation of 120 volt AC 20 amp, single-phase, 60 Hz electric lighting, appliances, tools and motor loads.

1

13

2

 

 

3

QUARTZ

 

 

 

 

HOURS

1/10

 

 

 

 

HOUR METER

20A

 

 

 

 

 

GFCI

 

TEST

RESET

12Vdc

IDLE

 

 

TEST

RESET

 

CONTROL

 

 

 

 

50A

ON OFF

20A

 

 

 

 

120V

 

120V

10A

 

 

 

 

 

20A

120V

20A

 

 

 

CIRCUIT BREAKERS - PUSH TO RESET

 

30A

GFCI

 

 

 

30A

30A

 

 

 

4)

120 Volt AC, 30 Amp Locking Receptacle – Supplies

 

electrical power for the operation of 120 Volt AC, 30 Amp, single-

 

phase, 60 Hz electrical lighting, appliance, tool and motor loads.

5)

120/240 Volt AC, 30 Amp Locking Receptacle

 

Supplies electrical power for the operation of 120 and/or 240 Volt

 

AC, 30 Amp, single-phase, 60 Hz, electrical lighting, appliance,

 

tool and motor loads.

6)

120/240 Volt AC, 50 Amp Receptacle – Supplies

 

electrical power for the operation of 120/240 Volt AC, 50 Amp,

 

single-phase, 60 Hz, welder or motor loads.

7)

Air Cleaner – Filters intake air as it is drawn into the engine.

8)

Choke Knob – Used when starting a cold engine.

4

Winter / Summer Valve – See “Cold Weather Operation.”

9)

 

120V/240V

 

120V/240V

30A

 

30A

30A

50A

120V

30A

6 5 10

Figure 5 - Generator Controls

(Section 2, page 12.)

10)Circuit Breakers (AC) – Each receptacle is provided with a push-to-reset circuit breaker to protect the generator against electrical overload.

11)Fuel Tank – Tank holds 16 U.S. gallons of fuel.

12)Grounding Lug – Ground the generator to an approved earth ground here. See page 9 for details.

7 11

1512

6

13)Idle Control Switch – The idle control runs the engine at normal (high) speeds when there is an electrical load present and runs the engine at idle (low) speeds when a load is not present.

14)Start/Run/Stop Switch – Controls the operation of the generator.

15)Oil Fill – Use this point to add oil to engine.

Figure 6 - Engine Control Panel

14

8

9

 

 

Page 8
Image 8
Generac 004451 ,004582, 004451, 004582 Operation, Know The Generator, 1512, Generator Controls, Engine Control Panel