Safety Rules

SAVE THESE INSTRUCTIONS – The manufacturer suggests that these rules for safe operation be copied and posted near the unit's installation site. Safety should be stressed to all operators and potential operators of this equipment.

EXHAUST & LOCATION HAZARDS

ELECTRICAL HAZARDS

Never operate in an enclosed area or indoors! NEVER use in the home, or in partly enclosed areas such as garages, even if doors and windows are open! ONLY use outdoors and far from open windows, doors, vents, and in an area that will not accumulate deadly exhaust.

The engine exhaust fumes contain carbon monoxide, which you cannot see or smell. This poisonous gas, if breathed in sufficient concentrations, can cause unconsciousness or even death.

Adequate, unobstructed flow of cooling and ventilating air is critical to correct generator operation. Do not alter the installation or permit even partial blockage of ventilation provisions, as this can seriously affect safe operation of the generator. The generator MUST be operated outdoors.

This exhaust system must be properly maintained. Do nothing that might render the exhaust system unsafe or in noncompliance with any local codes and/or standards.

Always use a battery operated carbon monoxide alarm indoors, installed according to the manufacturers instructions.

If you start to feel sick, dizzy, or weak after the generator has been running, move to fresh air IMMEDIATELY. See a doctor, as you could have carbon monoxide poisoning.

The generator produces dangerously high voltage when in operation. Avoid contact with bare wires, terminals, connections, etc., while the unit is running, even on equipment connected to the generator. Ensure all appropriate covers, guards and barriers are in place before operating the generator.

Never handle any kind of electrical cord or device while standing in water, while barefoot or while hands or feet are wet. DANGEROUS

ELECTRICAL SHOCK MAY RESULT.

The National Electric Code (NEC) requires the frame and external electrically conductive parts of the generator be properly connected to an approved earth ground. Local electrical codes may also require proper grounding of the generator. Consult with a local electrician for grounding requirements in the area.

Use a ground fault circuit interrupter in any damp or highly conductive area (such as metal decking or steel work).

Do not use worn, bare, frayed or otherwise damaged electrical cord sets with the generator.

In case of accident caused by electric shock, immediately shut down the source of electrical power. If this is not possible, attempt to free the victim from the live conductor. AVOID DIRECT CONTACT WITH THE VICTIM. Use a non-conducting implement, such as a rope or board, to free the victim from the live conductor. If the victim is unconscious, apply first aid and get immediate medical help.

FIRE HAZARDS

Gasoline is highly FLAMMABLE and its vapors are EXPLOSIVE. Do not permit smoking, open flames, sparks or heat in the vicinity while handling gasoline.

Never add fuel while unit is running or hot. Allow engine to cool completely before adding fuel.

Never fill fuel tank indoors. Comply with all laws regulating storage and handling of gasoline.

Do not overfill the fuel tank. Always allow room for fuel expansion. If tank is over-filled, fuel can overflow onto a hot engine and cause FIRE or an EXPLOSION. Never store generator with fuel in tank where gasoline vapors might reach an open flame, spark or pilot light (as on a furnace, water heater or clothes dryer). FIRE or EXPLOSION may result. Allow unit to cool entirely before storage.

Wipe up any fuel or oil spills immediately. Ensure that no combustible materials are left on or near the generator. Keep the area surrounding the generator clean and free from debris and keep a clearance of five

(5)feet on all side to allow for proper ventilation of the generator.

Do not insert objects through unit’s cooling slots.

Do not operate the generator if connected electrical devices overheat, if electrical output is lost, if engine or generator sparks or if flames or smoke are observed while unit is running.

Keep a fire extinguisher near the generator at all times.

2

Page 4
Image 4
Generac 005734-0, 005735-0 owner manual Safety Rules, Exhaust & Location Hazards, Fire Hazards, Electrical Shock MAY Result

005735-0, 005734-0 specifications

Generac 005735-0 and 005734-0 are high-performance energy solutions designed for residential and light commercial use, offering reliable power backup in various situations. Each model boasts distinct features and technologies that set them apart in the energy market.

The Generac 005735-0 is a 22 kW air-cooled automatic standby generator, engineered to deliver robust performance in the face of power outages. It is especially prized for its advanced Quiet-Test mode, which allows the generator to run at a lower speed for a five- or twelve-minute test, significantly reducing noise levels during routine checks. This feature makes it an excellent choice for neighborhoods with noise restrictions.

Designed with durability in mind, the 005735-0 utilizes a corrosion-resistant aluminum enclosure, ensuring longevity even in harsh weather conditions. Equipped with Generac's G-Flex technology, this model can operate efficiently while providing a steady power supply to essential appliances and systems like HVAC, refrigerators, and lights.

On the other hand, the Generac 005734-0 model features similar specifications but may serve a different market need with slight variations in design. Often marketed for slightly lower power requirements, this model provides a dependable 18 kW output.

Both generators incorporate a robust mobile link monitoring capability, allowing users to check the status and statistics of their generator remotely via a smartphone app. This feature adds a layer of convenience and peace of mind, allowing homeowners to monitor their systems from anywhere.

In terms of installation, these models are straightforward to set up, compatible with existing natural gas or liquid propane systems. They are also supported by Generac's extensive network of authorized installers, making the purchasing and installation process seamless for consumers.

Furthermore, both models come with a five-year limited warranty, affirming Generac's confidence in their reliability and durability. With the ability to provide instant power restoration during outages, the Generac 005735-0 and 005734-0 are ideal options for those prioritizing convenience and peace of mind in their homes.

Overall, these generators embody Generac's commitment to quality, innovation, and user-friendly technology, making them trusted choices for backup power solutions.