Generac 00784-2, 09290-4 Purpose And Scope Of The Manual, Equipment Description, Safety

Models: 00784-2, 09290-4

1 52
Download 52 pages 1.62 Kb
Page 22
Image 22

Section 1 – General Information

PRIMEPACT 50 and 70 (50Hz) Recreational Vehicle Generators

1.1PURPOSE AND SCOPE

OF THE MANUAL

These Installation Instructions have been prepared especially for the purpose of familiarizing installers and owners of the applicable equipment with the product's installation requirements. Give serious consideration to all information and instructions in the manual, both for safety and for continued reliable operation of the equipment.

Because of the different recreational vehicle models and the variations between the models, it would be extremely difficult, if not impractical, to provide detailed instructions for every possible installation. For that reason, instructions and illustrations in this manual are general in nature. Illustrations are not intended to serve as detailed installation blueprints.

The installation should comply strictly with all applicable codes, standards and regulations pertain- ing to the installation and use of this product. If any portion of this manual appears to be in conflict with such codes, standards or regulations, the applicable codes, standards or regulations must take prece- dence over the manual.

6.CSA Electrical Bulletin 946, available from the Canadian Standards Association, Housing and Constructions Materials Section, 178 Rexdale Boulevard, Rexdale, Ontario, Canada, M9W 1R3.

1.4EQUIPMENT DESCRIPTION

Instructions and information in this section pertain to Generac air-cooled generators. These generators are designed specifically for installing in recreational vehicles. They operate 230-volt, single-phase, 50- Hertz, AC electrical loads that require 20.8 amps (PP50) or 30.4 amps (PP70).

1.5GENERATOR ENGINE

OPERATING SPEED

The generator’s revolving field (rotor) is driven by a single-cylinder, four-cycle engine through a pulley and drive belt arrangement. The generator supplies 230 volts AC at 50 Hertz when the rotor is operating at 3,000 rpm. The drive belt arrangement allows the engine to operate at a lower speed than the rotor.

1.6GENERATOR AC CONNECTION SYSTEM

1.2SAFETY

Before handling, installing, operating or servicing this equipment, carefully read the “Notice to Installer” and “Safety Rules” on Pages 18 and 19. Comply with all safety rules to prevent death, personal injury or damage to equipment and/or property. Stress safety to all installers, operators and service technicians who work on this equipment.

This generator set is equipped with dual stator AC power windings as shown in Figure 1.1. These two- stator windings supply electrical power to customer electrical loads by means of a dual two-wire connec- tion system. Note, however, that the neutral is grounded.

Figure 1.1 – Connections for 230 Volts Only

1.3STANDARDS BOOKLETS

Installation, use and servicing of this equipment should comply strictly with published standards, as well as the manufacturer's recommendations. The following standards booklets (latest revision) are available from the sources indicated:

1.NFPA Standard 501C, “Standard for Recreational Vehicles,” available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

2.NFPA 70, “NFPA Handbook of the National Electric Code,” available same as Item 1.

3.ANSI C1-1975 and ANSI 119.2-1975, available from the American National Standards Institute, 1430 Broadway, New York, NY 10018.

4.ANSI A119.2/NFPA 501C, available from the Recreational Vehicle Association, 1896 Preston White Drive, Reston, VA 22090.

5.California Administrative Code, Title 25, avail- able from the State of California, Documents Section, P.O. Box 1015, North Highlands, CA 95660.

NOTE:

Do NOT connect loads in excess of circuit breaker ratings.

20 Generac® Power Systems, Inc.

Page 22
Image 22
Generac 00784-2, 09290-4 Purpose And Scope Of The Manual, Equipment Description, Generator Engine Operating Speed, Safety