Stopping the Engine

Unplug all electrical loads from generator panel receptacles. Never start or stop engine with electrical devices plugged in and turned on.

Put the Idle Control switch in the “Off” position.

Let engine run at no–load for 30 seconds to stabilize the internal temperatures of engine and generator.

Move Run/Stop switch to “Stop” position.

Close the fuel shut–off valve.

Operating Automatic Idle Control

This switch is designed to greatly improve fuel economy. When this switch is turned “ON”, the engine will only run at its normal high governed engine speed when an electrical load is connected. When the electrical load is removed, the engine will run at a reduced speed. With the switch “Off”, the engine will run at a constant high engine speed. Always have the switch “Off” when starting and stopping the engine.

Battery Safety

DANGER! Storage batteries give off explosive hydrogen gas while recharging. An explosive mixture will remain around the battery for a long time after it has been charged. The slightest spark can ignite the hydrogen and cause an explosion. Such an explosion can shatter the battery and cause blindness or other serious injury.

DANGER! Do Not permit smoking, open flame, sparks, or any other source of heat around a battery. Wear protective goggles, rubber apron and rubber gloves when working around a battery. Battery electrolyte fluid is an extremely caustic sulfuric acid solution that can cause severe burns. If spill occurs, flush area with clear water immediately.

Charging a Battery

Your generator has the capability of recharging a discharged 12 Volt automotive or utility style storage battery. Do Not use the unit to charge any 6 Volt batteries. Do Not use the unit to crank an engine having a discharged battery.

To recharge 12 Volt batteries, proceed as follows:

Check fluid level in all battery cells. If necessary, add ONLY distilled water to cover separators in battery cells. Do Not use tap water.

If the battery is equipped with vent caps, make sure they are installed and are tight.

If necessary, clean battery terminals.

Connect battery charge cable connector plug to panel receptacle identified by the words “12-VOLTS D.C.”

Connect battery charge cable clamp with red handle to the positive (+) battery terminal (Figure 5).

Figure 5 — Connect Battery Cable

Red

Black

 

Connect battery charge cable clamp with black handle to the negative (–)battery terminal (Figure 5).

Start engine. Let the engine run while battery recharges.

When battery has charged, shut down engine.

NOTE: Use an automotive hydrometer to test battery state of charge and condition. Follow the hydrometer manufacturer’s instructions carefully. Generally, a battery is considered to be at 100% state of charge when specific gravity of its fluid (as measured by hydrometer) is 1.260 or higher.

7

Page 7
Image 7
Generac 5500XL manual Stopping the Engine, Operating Automatic Idle Control, Battery Safety Charging a Battery

5500XL specifications

The Generac 5500XL is a robust portable generator designed to provide reliable and efficient power for various applications. Whether for home backup during outages, outdoor activities, or job sites, the 5500XL combines practicality and performance, making it a popular choice among consumers.

One of the standout features of the Generac 5500XL is its powerful 5,500-watt output, capable of running essential appliances and tools. This generator is equipped with a Generac 389cc OHVI engine, which is designed specifically for generator use, ensuring optimal performance, durability, and longevity. The engine is well-regarded for its ability to run smoothly for extended periods, thus providing users with peace of mind during power interruptions.

The 5500XL is designed with user convenience in mind. It features an easy-to-read LED display that provides vital information about power usage and operational status. The unit also boasts a reliable starting system, combining a manual pull start with an easy-start recoil mechanism, enabling quick and effortless ignition in various conditions.

Portability is another significant advantage of the Generac 5500XL. It is designed with a sturdy frame and high-quality wheels that allow for easy transportation across different terrains. The built-in handle is ergonomically designed, providing comfort during movement and ensuring stability when in use.

In terms of safety, the Generac 5500XL includes features like a low-oil shutdown, which automatically turns off the engine when oil levels are too low, protecting the engine from damage. Additionally, the generator is equipped with a circuit breaker that helps prevent overloads, ensuring safe operation at all times.

The generator also comes with multiple outlets, allowing users to connect various appliances and tools simultaneously. This versatility is particularly useful for construction sites, camping trips, and home use, where different power requirements must be met.

Finally, the 5500XL is built with durability in mind, featuring a tough, weather-resistant design that can withstand the elements. This makes it suitable for outdoor use, where exposure to rain or dust is a concern. Overall, the Generac 5500XL combines power, portability, and safety, making it an excellent choice for those in need of reliable portable energy solutions.