Generac Portable Products SE10000 Generator

Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 3600 watts

(3.6 kW) of power at 30 Amps. The outlet is protected by a 30 Amp push-to-reset circuit breaker.

120/240 Volt AC, 30 Amp Receptacle

240 Volt AC, 50 Amp Receptacle

Use a NEMA 14–50 plug with this receptacle. Connect a 4-wire cord set rated for 250 Volts at 50 Amps to the plug (Figure 12).

Figure 12 — 120/240 Volt, 50 Amp, Receptacle

Use a NEMA L14-30 plug with this receptacle. Connect a suitable 4-wire grounded cord set to the plug and to the desired load (Figure 11). The cord set should be rated for 250 Volts at 30 Amps (or greater).

Figure 11 — 120/240 Volt, 30 Amp, Locking Receptacle

Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 3600 watts

(3.6 kW) of power at 30 Amps or 240 Volt AC, 60 Hz, single phase loads requiring up to 7200 watts

(7.2 kW) of power at 30 Amps. The outlet is protected by a 30 Amp push–to–reset circuit breaker.

Use this receptacle to operate 240 Volt AC, 60 Hz, single phase loads requiring up to 10,000 watts (10.0 kW) of power.

CAUTION! Although this outlet states it has a 240 Volt AC, 50 Amp rating (up to 12,500 watts), the generator is only rated for 10,000 watts. Powering loads that exceed the wattage/ amperage capacity of the generator can damage it and cause serious injuries.

10