Generac Portable Products SE10000 Generator

DANGER! Engine exhaust contains carbon monoxide, a colorless and odorless gas which causes unconsciousness and death. Never run engine indoors or in poorly ventilated areas.

DANGER! Burn hazard. Temperature of muffler and nearby areas may exceed 150°F (65°C). Do not touch these areas on the generator.

Turn key switch to the “Start” position (Figure 7).

Figure 7 — Key Switch

IMPORTANT: Do not operate the electric starter continuously for more than 5 seconds, even if the engine does not start. Extended cranking can damage the starter motor.

NOTE: If the engine fails to start, set the key to the “Run” position and wait for about 10 seconds before retrying.

IMPORTANT: Never turn the key switch to the “Start” position while the engine is running. You could damage the starter motor.

When the engine starts, gradually open choke by pushing the choke knob in and keep it fully opened while running.

IMPORTANT! Do not overload the generator! Do not overload individual panel receptacles! These outlets are protected against overload with push-to-reset-type circuit breakers. If amperage rating of any circuit breaker is exceeded, that breaker opens and electrical output to that receptacle is lost. Read “Don’t Overload the Generator” on page 11 carefully.

If the Engine Will Not Start

Refer to the engine owner’s manual.

STOPPING THE ENGINE

Remove all electrical loads connected to unit’s receptacles. Never start or stop engine with devices plugged in and turned on.

Let engine run at no-load for 30 seconds to stabilize the unit’s internal temperatures.

Turn the key switch to the “Stop” position.

Close the fuel valve.

STOPPING THE ENGINE WITH THE FUEL VALVE

This procedure eliminates fuel from the carburetor. Use this method to stop the generator if you plan to store the generator over a long period. Fuel will clog the internal passages of carburetor if allowed to remain for an extended period.

Unplug all electrical loads connected to the unit’s receptacles. Never start or stop engine with devices plugged in and turned on.

Let engine run at no-load for 30 seconds to stabilize the internal temperatures of engine and generator.

Close the fuel valve while the engine is running and wait until the engine stops.

Set the key switch to the “Stop” position after the engine quits.

8