Integrated L-Band Up/Dn Converter LT3600

CG-1309

 

 

SECTION 2

Installation

2.0 INTRODUCTION

This section defines the installation require- ments by which the Integrated L-Band Up/Dn Converter will meet the published specifications.

2.1UNPACKING AND INSPECTION

Remove the unit from its shipping container and inspect for any damage sustained during shipment. Save the packing material for reshipment back to the factory or to another site. Report any damage to the shipping forwarder in accordance with required procedures.

2.2INSTALLATION REQUIREMENTS

The LT-3600 is designed for mounting in a standard EIA 19-inch rack. The unit must be supported on the sides and space must be allowed at the side of the unit to permit the flow of cooling air. The unit should be installed in an environment that is within the environ- mental envelope described in Table 1-1. Primary power must be made available that is within the specified limits.

2.3MECHANICAL INSTALLATION

The chassis is equipped with threaded inserts on either side for the installation of slides. Slides are not provided with the unit. The front panel is equipped with slots to accommodate user-supplied retaining screws.

2.4.1 Power Input

This connector is an IEC 320-C14 male and will accept any compatible mating connector. The power cord supplied as standard with the unit is equipped with a NEMA 5-15P male plug at the opposite end and is compatible with most 115 VAC supplies. The unit is manufact- ured with a Universal Input Power supply that will accept voltages in the range of 115 or 230 +/-15% VAC.

CAUTION

DAMAGE MAY RESULT IF THE INCORRECT VOLTAGE IS APPLIED TO THE UNIT.

2.4.2 L-Band Output (J10)

This connector is selectable as an SMA or N- Type female. The mate (not supplied) should be compatible with the 50-ohm coax used to connect to the system.

CAUTION

DC OUTPUT CURRENT MAY BE PRESENT ON J4 AND J10 DEPENDING ON POWER OPTIONS SUPPLIED FOR THE SSPB AND LNB.

2.4.3 IF Input (J9)

This connector is a BNC female. The male mate (not supplied) should be compatible with the 50-ohm coax used to connect to the system.

2.4.4 IF Output (J3)

CAUTION

MOUNTING THE UNIT BY ONLY THE FRONT PANEL WILL CAUSE EXTENSIVE DAMAGE.

This connector is a BNC female. The male mate (not supplied) should be compatible with the 50-ohm coax used to connect to the system.

2.4.5 L-Band Input (J4)

2.4 ELECTRICAL CONNECTIONS

All electrical connections are made to the rear panel of the unit. The following describes the rear panel connectors and its interface requirements. The chassis ground is a #10-32 lug on the back panel.

This connector is selectable as an SMA or N- Type female. The male mate (not supplied) should be compatible with the 50-ohm coax used to connect to the system.

Page 12

Page 12
Image 12
General Dynamics UP/DN CONVERTER L-BAND, LT-3600 manual Installation

UP/DN CONVERTER L-BAND, LT-3600 specifications

The General Dynamics LT-3600 is an advanced UP/DN converter designed specifically for L-band applications, tailored to meet the rigorous demands of modern communication and broadcasting systems. Known for its reliability and versatility, the LT-3600 supports a wide range of operational environments, making it a preferred choice for military, aerospace, and commercial users.

One of the standout features of the LT-3600 is its ability to provide high-performance frequency translation with minimal signal degradation. The device operates within a frequency range typically from 950 MHz to 2150 MHz, allowing it to effectively handle various input and output frequencies, which is crucial for seamless integration into existing systems.

The LT-3600 employs advanced digital signal processing (DSP) technologies that enhance its performance in terms of linearity, noise figures, and phase stability. This results in superior signal clarity and reduced interference, ensuring that the converted signals maintain their integrity over long distances. The use of high-quality mixers and filters further contributes to its exceptional performance metrics, making it suitable for critical applications where signal fidelity is paramount.

In terms of usability, the LT-3600 boasts a user-friendly interface that facilitates ease of setup and operation. It is equipped with intuitive controls and indicators that provide real-time feedback on operational status, which is essential for monitoring performance during live operations. The device also offers options for both manual and remote control, enhancing its flexibility for different operational requirements.

Another significant characteristic of the LT-3600 is its robust design, featuring rugged components that can withstand adverse environments. The unit is engineered to comply with military standards, making it suitable for deployment in harsh conditions, including extreme temperatures and humidity. This reliability is critical for military and aerospace applications where equipment failures can lead to severe consequences.

Additionally, the LT-3600 supports various modulation schemes and can be easily integrated into systems requiring diverse communication protocols. This adaptability ensures that users can customize the unit to meet specific requirements, enhancing its appeal across multiple industries.

In summary, the General Dynamics LT-3600 UP/DN converter stands out for its advanced features, including superior signal quality, user-friendly operation, and rugged reliability. Its combination of innovative technologies and practical design makes it an essential component for anyone seeking high-performance L-band solutions in challenging environments.