General Dynamics UP/DN CONVERTER L-BAND, LT-3600 manual Section, General Information

Models: UP/DN CONVERTER L-BAND LT-3600

1 26
Download 26 pages 9.91 Kb
Page 6
Image 6

Integrated L-Band Up/Dn Converter LT3600

CG-1309

 

 

SECTION 1

General Information

1.0 INTRODUCTION

This manual contains installation, operation, and maintenance information for the Integrated L-Band Up/Dn Converter manufactured by VertexRSI, Longview, Tx. Information is organized according to section. Within each section the pages, figures and tables are numbered by section and by order of appear- ance within the section. Unless otherwise noted, any information about the unit applies to the LT-3600, Base Part Number 201667.

1.1 SAFETY INFORMATION

This equipment has been designed to minimize exposure of personnel to hazards.

WARNING

A continuous safety earth ground must be provided from the main power source through the main power cord. This is provided in the power cable shipped with the unit. If this power cord is damaged, it should be replaced with cord of equal or better specifications. This cord can be obtained from VertexRSI.

Servicing instructions are for use by trained personnel only. To avoid dangerous electric shock, do not perform any servicing unless qualified to do so. Do not replace components with the power cord connected to the equipment.

WARNING

Some of the adjustments described in this manual are performed with power applied while protective covers are removed.

Always be careful not to come on contact with dangerous voltages while performing these procedures, and never work alone.

With power applied to the unit and the cover removed, be aware that a rotating fan is operating.

1.2 GENERAL INTRODUCTION

This manual provides operation and service instructions for the Integrated L-Band Up/Dn Converter. The unit consists of a power supply, forced-air cooling system, microprocessor- based CCA (circuit card assembly) and control circuitry and the modules required for up and down conversion. It incorporates extensive monitor and control functions that are accessible from the front panel as well as through a remote serial bus. A general description of the front and rear panels is given in Sections 1.5 and 1.6. A description of the Keypad and Display can be found in Section 3.

The Integrated L-Band Up/Dn Converter is housed in an enclosure destined for mounting in a standard EIA 19-inch rack, requiring a 1.75-inch high vertical space.

1.3 PURPOSE OF EQUIPMENT

The Integrated L-Band Up/Dn Converter is a fully synthesized up and down converter covering 575 or 1000 MHz bandwidth receiving RF frequencies in up to 125 kHz steps. The unit incorporates extensive monitor and control functions that are accessible from the front panel as well as through a remote RS- 232/422/485 bus.

The LT-3600 can be configured to accommodate various requirements involving an IF of 70 or 140 MHz, non-inverted or inverted spectrum, with standard or high- stability 10 MHz reference oscillator or any combination the user desires. Combined with jumper selectable and user programmable options, the LT-3600 is flexible to user requirements.

Page 6

Page 6
Image 6
General Dynamics UP/DN CONVERTER L-BAND, LT-3600 manual Section, General Information

UP/DN CONVERTER L-BAND, LT-3600 specifications

The General Dynamics LT-3600 is an advanced UP/DN converter designed specifically for L-band applications, tailored to meet the rigorous demands of modern communication and broadcasting systems. Known for its reliability and versatility, the LT-3600 supports a wide range of operational environments, making it a preferred choice for military, aerospace, and commercial users.

One of the standout features of the LT-3600 is its ability to provide high-performance frequency translation with minimal signal degradation. The device operates within a frequency range typically from 950 MHz to 2150 MHz, allowing it to effectively handle various input and output frequencies, which is crucial for seamless integration into existing systems.

The LT-3600 employs advanced digital signal processing (DSP) technologies that enhance its performance in terms of linearity, noise figures, and phase stability. This results in superior signal clarity and reduced interference, ensuring that the converted signals maintain their integrity over long distances. The use of high-quality mixers and filters further contributes to its exceptional performance metrics, making it suitable for critical applications where signal fidelity is paramount.

In terms of usability, the LT-3600 boasts a user-friendly interface that facilitates ease of setup and operation. It is equipped with intuitive controls and indicators that provide real-time feedback on operational status, which is essential for monitoring performance during live operations. The device also offers options for both manual and remote control, enhancing its flexibility for different operational requirements.

Another significant characteristic of the LT-3600 is its robust design, featuring rugged components that can withstand adverse environments. The unit is engineered to comply with military standards, making it suitable for deployment in harsh conditions, including extreme temperatures and humidity. This reliability is critical for military and aerospace applications where equipment failures can lead to severe consequences.

Additionally, the LT-3600 supports various modulation schemes and can be easily integrated into systems requiring diverse communication protocols. This adaptability ensures that users can customize the unit to meet specific requirements, enhancing its appeal across multiple industries.

In summary, the General Dynamics LT-3600 UP/DN converter stands out for its advanced features, including superior signal quality, user-friendly operation, and rugged reliability. Its combination of innovative technologies and practical design makes it an essential component for anyone seeking high-performance L-band solutions in challenging environments.