Atlas & Yukon Second Stage
Final Testing Procedures | 6 |
| |
| s e c t i o n |
CAUTION: If the regulator has been upgraded for use with EAN/ Nitrox, it is important to pressurize and flow test the regulator using only
1.Connect the IP Test Gauge (PN
NOTE: Check to ensure that the knurled knob of the Inline Adjustment Tool is set to the inner dimple, nearest to the slotted drive, for the S.K.O. second stage. The extended inlet coupling of the SideKick second stage will requre the knurled knob to be set to the outer dimple, in order to pro- vide the deeper reach that is needed for the slotted drive to make contact with the orifice.
2.Install the
3.Install the
first stage regulator that has been verified to be properly serviced, with a stable intermediate pressure of 140 (±5) psi . Apply a torque wrench with a b"
Fig. 20 - Inline Adjustment Tool w/ IP Gauge
CAUTION: If the second stage has been cleaned and ser- viced for use with EAN/ Nitrox, it is important to connect it with a first stage that has also been cleaned and serviced accordingly, and to use only
Copyright ©2001 Liberty Group | 28 |