  | General Troubleshooting | 
  | 
Problem | 
  | 
  | What To Do | 
  | 
Opener does not run  | 
  | 1.  | Check Lock switch on Wall Control Installation Poster.  | 
  | 
  | 
  | |||
from Wall Control  | 
  | 2.  | Check Power Source:  | 
  | 
  | 
  | 
  | • For Grounded Plug Connection.  | 
  | 
  | 
  | 
  | – Plug a lamp into the electrical outlet used for the door opener..  | 
  | 
  | 
  | 
  | a.. If lamp lights, power source is good.  | 
  | 
  | 
  | 
  | b.. If lamp does not light, check fuse or circuit breaker.  | 
  | 
  | 
  | 
  | • For Permanent Wiring Connection.  | 
  | 
  | 
  | 
  | – Check fuse or circuit breaker.  | 
  | 
  | 
  | 3.  | Check connections (see Wall Console Installation on Installation Poster):  | 
  | 
  | 
  | 
  | • At Power Head Terminals and Wall Control.  | 
  | 
  | 
  | 
  | 
  | 
  | 
Door Opener starts  | 
  | 1.  | Check Wires to ensure that they are not cut (Staples can cut insulation and short Wires)  | 
  | 
for no apparent reason  | 
  | 2.  | Replace any shorting Staples and shorted Wires. | 
  | 
  | 
  | Was Remote Control lost or stolen? If so, erase all Remote Control codes from Receiver’s memory  | ||
  | 
  | 3.  | and reprogram for remaining remote controls.. (See Erase All Receiver Memory on page 8)..  | |
  | 
  | Ensure that no Buttons are stuck   | 
  | |
  | 
  | 
  | 
  | 
  | 
Door starts down, then  | 
  | 1.  | Check Close Limit Switch setting (page 7 and poster).. Adjust as needed.  | 
  | 
stops before it is  | 
  | 2.  | Check Force Setting (pages 7).. Adjust as needed.  | 
  | 
completely closed  | 
  | 3.  | Check for shorted wires..  | 
  | 
  | 
  | 
  | 
  | 
  | 
Door starts down, then  | 
  | 1.  | If a new installation, check Door Arm position.  | 
  | 
stops and goes back up  | 
  | 2..  | Check operation of Contact Reverse function.  | 
  | 
  | 
  | 3..  | Check   | 
  | 
  | 
  | 4..  | Check  | 
  | 
  | 
  | 5..  | Check Close Force adjustment (see Set Limit Switches and Force Controls on pages 7).. Adjust as needed.  | |
  | 
  | 6..  | Check garage door for binding..  | 
  | 
  | 
  | 
  | 
  | 
  | 
Door will only run closed  | 
  | 1..  | Check Open Limit Switch for a short circuit and for proper wiring.  | 
  | 
  | 
  | 2..  | Check Open Force adjustment (see Set Limit Switches and Force Controls on pages 7).. Adjust as needed.  | |
  | 
  | 3..  | Check condition of garage door and door spring(s).  | 
  | 
  | 
  | 4..  | WARNING: If you suspect a problem with the garage door hardware or springs, contact a Genie  | |
  | 
  | 
  | Factory Authorized Dealer for service, or contact Customer Service at   | 
  | 
  | 
  | 5..  | Check Position of Lock Switch on Console.. | 
  | 
Door will only run open  | 
  | 1..  | Check   | |
  | 
  | 2..  | (page 10)..  | 
  | 
  | 
  | Check Close Limit Switch for a short circuit and for proper wiring.  | 
  | |
  | 
  | 3..  | Check Close Force adjustment (see Set Limit Switches and Force Controls on pages 7).. Adjust as needed..  | |
  | 
  | 
  | 
  | |
Lights will not turn off  | 
  | 1..  | Disconnect Wires connecting Pushbutton to Power Head (see Pushbutton Installation on poster)..  | |
  | 
  | 2..  | Check their condition and either replace or reconnect.. | 
  | 
  | 
  | Until a replacement Wall Console can be obtained, disconnect Wall Console and use only Remote Controls  | ||
  | 
  | 
  | or Wireless Keypad to operate Opener..  | 
  | 
  | 
  | 3. Check for   | 
  | |
  | 
  | 
  | 
  | |
Door starts up,  | 
  | 1.  | Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly  | |
but stops before it is  | 
  | 
  | balanced as detailed in Maintenance Section.  | 
  | 
completely open  | 
  | 2..  | WARNING: If you suspect a problem with the garage door hardware or springs, contact a Genie Factory  | |
  | 
  | 3..  | Authorized Dealer for service, or contact Customer Service at   | .  | 
  | 
  | Check Open Limit Switch for a short circuit and for proper wiring.  | 
  | |
  | 
  | 4..  | Check Open Force adjustment (see Set Limit Switches and Force Controls on pages 7).. Adjust as needed..  | |
  | 
  | 
  | 
  | |
Operator runs, but door | 
  | 1..  | Ensure Carriage Assembly is engaged to Carriage Slide (see Install Carriage Assembly onto Rails on Installation Poster)..  | |
does not move | 
  | 2..  | Check Force adjustment (see Set Limit Switches and Force Controls on pages 9 and 10).. Adjust as needed.  | |
Wall Console Vacation  | 
  | 1..  | Ensure Carriage Assembly is in contact with Close Limit Switch.  | 
  | 
Lock function does  | 
  | 2..  | Check when door is fully closed, that Carriage activates Close Limit Switch.. If not, adjust position of Close  | |
not work  | 
  | 
  | Limit Switch (See pages 7)..  | 
  | 
  | 
  | 
  | 
  | 
  | 
Noisy Operation  | 
  | 1..  | Be sure all fasteners are tight.  | 
  | 
  | 
  | 2. Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly  | ||
  | 
  | 
  | balanced as described in Maintenance Section (page 10)..  | 
  | 
For Help, call   | 11  |