Genie 3681036666 troubleshooting Guide, Safe-T-Beam System Self-Diagnostic Troubleshooting, Genie

Models: 3681036666

1 14
Download 14 pages 1.8 Kb
Page 10
Image 10
Scheduled Maintenance

Scheduled Maintenance

AMonthly:

Door springs and door hardware:

Oil door roller, bearings, and hinges using silicone lubricant or light oil..

1-800-35-GENIE.WARNING

Do not operate door automatically or manually if springs are broken.. Contact a Genie Factory Authorized Dealer for service or call Customer Service at 1-800-35-GENIE..

Balance Door..

Close door.

Release Carriage Assembly from Rail Assembly by pulling down on Emergency Release Knob..

Raise door manually 3’- 4’ and verify that door stays at that position.. See Check Step 2 on page 4..

NOTE

When the door is 3’ - 4’ above the ground, the door should stay open.. Slight movement is acceptable.. If the door moves too much, contact a Genie Factory Authorized Dealer for service or call Customer Service at

1-800-35-GENIE.

troubleshooting Guide

Reattach Carriage Assembly to Rail Assembly:

a..Pull the Emergency Release Knob toward Power Head..

b..Close door..

Contact Reverse Test.

– Perform Adjustment Step 2 on page 8..

troubleshooting GuideWARNING

If the door fails to reverse on contact with the board, adjust the Close Force Control as specified in Set Limit Switches and Force Controls on page 9.. If the Opener still fails, contact a Genie Factory Authorized Dealer for service or call Customer Service at 1-800-35-GENIE..

FCC AND IC CERTIFIED

All devices comply with Part 15 of the FCC Rules.. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, includ- ing interference that may cause undesired operation..

BAs Needed:

Replace Light Bulb

Safe-T-Beam® System Self-Diagnostic Troubleshooting

Source (Red LED)

Sensor (Green LED)

Possible Problem
Solution

ON

ON

Normal operation

None required

OFF

OFF

• Power Head not powered

• Check breakers, fuses, plugs

• Wiring from Power Head bad

• Check wiring for obvious shorts

 

 

 

 

 

 

OFF

ON

• Wiring to Source missing or bad

• Check wiring

• Power has been interrupted

• Remove power and reapply

 

 

2 BLINKS, Pause

 

• Beam not aligned

• Check Source, Sensor alignment

(Repeat)

ON

• Beam obstructed

• Check for obstruction

 

 

• Sensor defective

• Contact Customer Service

2 BLINKS, Pause

OFF

• Wire to Sensor missing or bad

• Check wiring

(Repeat)

• Sensor defective

• Contact Customer Service

 

 

 

 

 

3 BLINKS, Pause

 

• Sensor receiving interference

• Determine source of interference

(Repeat)

 

 

• Check for sunlight or another

 

ON

 

opener on nearby door

 

 

• Contact Customer Service

 

 

 

4 BLINKS, Pause

ON

• Source not sending pulses

• Contact Customer Service

(Repeat)

• Source defective

• Contact Customer Service

 

 

 

 

 

10

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

Page 10
Image 10
Genie 3681036666 troubleshooting Guide, Safe-T-Beam System Self-Diagnostic Troubleshooting, Scheduled Maintenance, Genie