Genie GS-1932 At the Platform Controls, Test the Up/Down Functions, Test the Auxiliary Lowering

Models: GS-1932 GS-1532 GS-1930 GS-1530 CE

1 36
Download 36 pages 5.86 Kb
Page 19
Image 19
Test the Up/Down Functions

Third Edition • Second Printing

Operator's Manual

 

 

 

 

Test the Up/Down Functions

The audible warnings on this machine and the standard horn all come from the same central alarm. The horn is a constant tone. The descent alarm sounds at 60 beeps per minute. The alarm that goes off when the pothole guards have not deployed sounds at 300 beeps per minute. The alarm that goes off when the machine is not level sounds at 600 beeps per minute. An optional automotive-style horn is also available.

8 Activate the up function.

Result: The platform should raise.

9 Activate the down function.

Result: The platform should lower. The descent alarm should sound while the platform is lowering.

Test the Auxiliary Lowering

10 Activate the up function and raise the platform approximately 60 cm.

11Pull the auxiliary lowering knob located behind the entry ladder.

Result: The platform should lower. The descent alarm will not sound.

12 Turn the key switch to platform control.

FUNCTION TESTS

At the Platform Controls

Test Emergency Stop

13Push in the platform red Emergency Stop button to the off position.

Result: No functions should operate.

Test the Horn

14 Pull the red Emergency Stop button out to the on position.

15 Push the horn button.

Result: The horn should sound.

Test the Function Enable Switch

16Do not hold the function enable switch on the control handle.

17Slowly move the control handle in the direction indicated by the blue arrow, then in the direction indicated by the yellow arrow.

Result: No functions should operate.

Test the Up/Down Functions

18 Press the lift function select button.

19 Press and hold the function enable switch on the control handle.

20Slowly move the control handle in the direction indicated by the blue arrow.

Result: The platform should raise. The pothole guards should deploy.

Part No.1000032

GS-1530GS-1532GS-1930GS-1932

17

Page 19
Image 19
Genie GS-1932, GS-1930, CE At the Platform Controls, Test the Up/Down Functions, Test the Auxiliary Lowering, Test the Horn