Operator's Manual | Third Edition • Second Printing |
|
|
|
|
Function Tests
Do Not Operate Unless:
You learn and practice the principles of safe machine operation contained in this operator's manual.
1Avoid hazardous situations.
2Always perform a
3Always perform function tests prior to use.
Know and understand the function tests before going on to the next section.
4Inspect the workplace.
5Only use the machine as it was intended.
Fundamentals
The function tests are designed to discover any malfunctions before the machine is put into service. The operator must follow the
A malfunctioning machine must never be used. If malfunctions are discovered, the machine must be tagged and removed from service. Repairs to the machine may only be made by a qualified service technician, according to the manufacturer's specifications.
After repairs are completed, the operator must perform a
1Select a test area that is firm, level and free of obstruction.
2Be sure the battery pack is connected.
At the Ground Controls
3Pull out the platform and ground red Emergency Stop buttons to the on position.
4Turn the key switch to ground control.
5Observe the LED diagnostic readout on the platform controls.
Result: The LED should look like the picture at right.
Test Emergency Stop
6Push in the ground red Emergency Stop button to the off position.
Result: No functions should operate.
7Pull out the red Emergency Stop button to the on position.
16 | Part No.1000032 |