Third Edition • Second Printing | Operator's Manual |
|
|
|
|
Check the Batteries
Proper battery condition is essential to good machine performance and operational safety. Improper fluid levels or damaged cables and connections can result in component damage and hazardous conditions.
This procedure does not need to be performed on machines with sealed or
Electrocution hazard. Contact with hot or live circuits may result in death or serious injury. Remove all rings, watches and other jewelry.
Bodily injury hazard. Batteries contain acid. Avoid spilling or contacting battery acid. Neutralize battery acid spills with baking soda and water.
Perform this test after fully charging the batteries.
1Put on protective clothing and eye wear.
2Be sure that the battery cable connections are tight and free of corrosion.
3Be sure that the battery
4Remove the battery vent caps.
5Check the battery acid level of each battery. If needed, replenish with distilled water to the bottom of the battery fill tube. Do not overfill.
6Install the vent caps.
MAINTENANCE
Scheduled Maintenance
Maintenance performed quarterly, annually and every two years must be completed by a person trained and qualified to perform maintenance on this machine according to the procedures found in the service manual for this machine.
Machines that have been out of service for more than three months must receive the quarterly inspection before they are put back into service.
Part No.1000032 | 15 |