GENERAL SAFETY
GENERAL SAFETY PROCEDURES
AVOID ELECTRICAL POWER LINES
DANGER
REQUIRED CLEARANCE FOR NORMAL VOLTAGE IN
OPERATION NEAR HIGH VOLTAGE POWER LINESAND
OPERATION IN TRANSIT WITH NO LOAD AND BOOM
OR MAST LOWERED.
Normal Voltage, kV | Minimum Required | |
(Phase to Phase) | Clearance, ft. (m) | |
Operation Near High Voltage Power Lines |
|
|
to 50 | 10 | (3.05) |
Over 50 to 200 | 15 | (4.60) |
Over 200 to 350 | 20 | (6.10) |
Over 350 to 500 | 25 | (7.62) |
Over 500 to 750 | 35 | (10.67) |
Over 750 to 1000 | 45 | (13.72) |
Operation in Transit With No Load and Boom Lowered |
| |
to 0.75 | 4 (1.22) | |
Over 0.75 to 50 | 6 ((1.83) | |
Over 50 to 345 | 10 | (3.05) |
Over 345 to 750 | 16 | (4.87) |
Over 750 to 1000 | 20 | (6.10) |
|
|
|
WARNING
Always remain completely inside the cab enclosure while operating the machine.
WARNING
Never operate this machine under the influence of drugs, alcohol and/or medication which can cause drowsiness.
WARNING
Never transport or lift personnel into position with this forklift. It is not designed as a personnel lifting device.