Problem

 

 

Possible Cause

Solution

 

 

 

 

 

 

Contact your local distributor to check the

The

 

 

door

Safety devices are on

Photocell and Safety Device. (keep the device

 

 

 

 

clean)

automatically

 

 

 

 

 

 

 

open

but

doesn’t

 

 

 

 

 

 

close.

 

 

 

“REDA 1”, “REDA 2” contacts

Check the “REDA 1”, “REDA 2” contacts are

 

 

 

 

 

 

 

 

are on.

working properly. Remove the obstacles.

 

 

 

 

 

 

The

 

 

door

The sensor detects something

Check the “REDA 1”, “REDA 2” contacts are

automatically

opens

moving.

working properly. Remove the obstacles.

and closes by itself.

 

 

 

 

 

 

 

The

Encoder may be

When the encoder is incorrect, please contact

 

 

 

 

incorrect.

your local distributor.

The

 

 

door

 

 

 

 

 

The AD-425S stops operating

 

automatically

stops

Make sure the door swing freely without any

before

reaching the

automatically when the door

obstruction.

preset destination.

is interrupted for three times.

 

The input power is low.

Make sure the Power input is working properly.

 

 

 

 

 

 

 

 

 

 

LED(Relay)

 

 

The

direction of Operating

Adjust the F/R. (Restart the power)

indicates

in

the

opposite status.

Arm

is incorrect.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fuse burn out.

Replace fuse.250V, 5A

LED(Charge)

not

 

 

 

working.

 

 

Wires loose

Check the wiring

 

 

 

 

 

 

 

 

 

 

 

Maintenance ( every 6 months)

Turn the power off. Please ensure and switches are “OFF”

zClean and lubricate all moving components.

zCheck that all screws are well tightened.

zCheck all wiring is working normally.

Turn the power on. Please ensure that switches are “ON”.

zCheck the door movement stability.

zCheck the condition of the hinges.

zCheck all functions of the AD-425 are working normally. .

Normal Operation:

During maintenance, in case of malfunction or emergency, please ensure the power is “OFF” and the operator is working manually. For the safety reason, we recommend user do not install this operator with a Fail-Secure Electric Locks (Power to open).