INSTALLATION INSTRUCTIONS

Connect to the electricity supply

Warning: This appliance must be earthed.

The appliance must be installed by a competent electrician using a double pole control unit of 32 ampere minimum capacity with 3mm minimum contact separation at all poles.

We recommend that the appliance is connected by a qualified electrician who is a member of the N.I.C.E.I.C. and who will comply with the I.E.E. and local regulation.

1.Access to the mains terminal is gained by opening the terminal block cover at the rear of the appliance (use a small flat-bladed screwdriver).

2.Connection should be made with 6.0mm2 flexible twin and earth cable.

3.First strip the wires, then push the cable through the cable clamp in the terminal block cover.

4.Connect the cable to the terminal block using an 8mm socket and tighten the cable clamp screw (see diagram).

5.Close the terminal box, ensuring that the cover is engaged on the locking tabs.

44