6.Loosen the bevel lock (16) and set the saw arm (5) at 0º bevel (the blade at 90º to the mitre table). Tighten the bevel lock (16) (Fig. S).
7.Place a set square against the table (21) and the flat part of the blade.
Note. Make sure that the square contacts the flat part of the saw blade, not the teeth.
8. Rotate the blade by hand
and check the
9.The edge of the set square and the saw blade should be parallel.
10.If the saw blade angles away from the set square, adjust as follows.
11. Use a 13mm wrench or | T |
| |
adjustable wrench to loosen |
|
the lock nut securing the 0° |
|
bevel adjustment screw |
|
(34)(Fig. T). Also, loosen the bevel lock (16).
12.Adjust the 0° bevel
adjustment screw (34) with
the 6mm hex key to bringU the saw blade into alignment
with the square.
13.Loosen the Phillips head screw holding the pointer of the bevel scale (17) and adjust the position of the pointer so that it accurately indicates zero on the scale. Retighten the screw (Fig. U).
14. Retighten the bevel lock
(16) and the lock nutV securing the 0° bevel
adjustment screw (34).
Note. The above procedure can also be used to check the angle of the saw blade to the table at 45º bevel angle. The 45° bevel adjustment screw (33) is on the opposite side of the saw arm (Fig. V).
Setting the fence square with the table
1.Make sure that the electrical plug is removed from the power point.
2.Push the saw arm (5) down to its lowest position and engage the release knob (6) to hold the saw arm in the transport position.
3.Loosen the mitre lock (25).
4.Rotate the table (21) until the pointer is positioned at 0º.
5.Tighten the mitre lock (25).
6.Using the 6mm hex key
| provided, loosen the four | W | |
| screws securing the fence (18) |
| |
| to the base (Fig. W). |
| |
7. | Place a square against the |
| |
| fence (18) and alongside |
| |
| the blade. |
| |
8. | Adjust the fence (18) until it is |
| |
| square with the blade. |
| |
9. | Tighten the screws securing |
| |
X | |||
| the fence (18). | ||
|
|
10.Loosen the Phillips head screw holding the pointer of the mitre scale (22) and adjust it so that it accurately indicates the zero position on the mitre scale (Fig. X).
11.Retighten the screw securing the mitre scale pointer.
13