Flash codes indicate the nature of an abnormal condition directly from the SHARK Information Gauge. Without the use of any servicing tools, the condition can be simply diagnosed.

Flash

Description

 

Code

 

 

 

 

 

1

User Fault

Possible stall timeout or user error. Release

 

 

the joystick to neutral and try again.

2

Battery Fault

Check the batteries and cabling. Try charging

 

 

the batteries. Batteries may require replacing.

 

 

 

3

Right Motor Fault

Check the right motor, connections and

 

 

cabling.

4

Left motor fault

Check the left motor, connections and

 

 

cabling.

5

Right park brake fault

Check the right park brake, connections and

 

 

cabling.

6

Left park brake fault

Check the left park brake, connections and

 

 

cabling.

7

SHARK Control Unit Fault

Check the SHARK Communications Bus con-

 

 

nections and wiring. Replace the Control Unit

 

 

 

8

SHARK Power Module

Check SHARK connections and wiring.

 

Fault

Replace the Power Module.

9

SHARK Communications

Check SHARK connections and wiring.

 

Fault

Replace the SHARK Control Unit.

10

Unknown Fault

Check all connections and wiring. Consult a

 

 

service agent.

The SHARK modules are not user serviceable. Do not attempt to repair Shark modules.

Note that joystick OONAPU (Out Of Neutral At Power Up) is not a fault. Simply by removing your hand from the joystick and allowing it to return to the neutral position, the fault will immediately clear. If the condition persists after removing your hand, the joystick may be damaged. Consult a Service agent.

25