Electrical Safety
Owner’sManual 9
ENGLISH
Electrical Safety

Electrical Data

115V~ 230V~

Power cord may include a current
interrupter device. A test and reset button is
provided on the plug case. The device
should be tested on a periodic basis by first
pressing the TEST button and then the
RESET button. If the TEST button does not
trip or if the RESET button will not stay
engaged, discontinue use of the air
conditioner and contact a qualified service
technician.
Use Wall Receptacle Power Supply
Standard 125V, 3-wire grounding
receptacle rated 15A, 125V AC
Standard 250V, 3-wire grounding
receptacle rated 15A, 250V AC
Use 15 AMP. time
delay fuse or 15 AMP.
circuit breaker.
Use 20 AMP. time
delay fuse or 20 AMP.
circuit breaker.
Standard 250V, 3-wire grounding
receptacle rated 20A, 250V AC
Neverpush the test button during
operation
Otherwisethis plug can damaged.
Thisdevice contains chemical, including
lead,known to the State of California to
causecancer, and birth defects or other
reproductiveharm.
Washhands after handling.
Donot remove, modify or immerse this plug.
Ifthis device trips, the cause it to be
correctedbefore further use.
The conductors inside this cord are
surrounded by shields,which monitor
leakage current.
These shields are not grounded.
<
Periodicallyexamine the cord for any
damage.Do not use this product in the
eventthe shields become exposed.
Avoidshock hazard, this unit can not
be user serviced opening the tamper
resistant.Sealed por tion of the unit
voids all warrantiesand performance
claims.This unit not intended for use
as an on-off switch.
The shape maybe different according to its model.
NOTICE
DO NOTUSE AN EXTENSION CORD on 230,
208, and 230/208Volt units.
All wiring should be made in accordance with local
electrical codes and regulations.
Aluminumhouse wir ing maypose special
problems.Consult a qualified electrician.
NOTICE