Maintenance and Service

CommonProblemsandSolutions

Troubleshooting Tips Save time and money!

Review the chart below first and you may not need to call for service.

NormalOperation

You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.

You may hear the thermostat click when the compressor cycles on and off.

Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.

The fan may run even when the compressor does not.

Troubleshooting

Problem

Possible Causes

What To Do

 

 

 

 

The air conditioner is

• Make sure the air conditioner plug is pushed

 

unplugged.

completely into the outlet.

The fuse is blown/circuit • Check the house fuse/circuit breaker box and replace

breaker is tripped.

the fuse or reset the breaker.

Power failure.• If power failure occurs, turn the mode control to OFF.

Air conditioner

When power is restored, wait 3 minutes to restart the

does not start

air conditioner to prevent tripping of the compressor

 

 

overload.

The current interrupter • Press the RESET button located on the power cord

device is tripped.plug. If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

 

Airflow is restricted.

• Make sure there are no curtains, blinds, or furniture

 

 

blocking the front of the air conditioner.

 

TEMP Control set too

• Set the TEMP control to a lower number.

 

higher number.

 

Air conditioner

The air filter is dirty.

• Clean the filter at least every 2 weeks.

 

See the operating instructions section.

does not cool as it

 

 

 

should

The room may have been

• When the air conditioner is first turned on,

 

hot.

you need to allow time for the room to cool down.

Cold air is escaping. • Check for open furnace floor registers and cold air returns.

Set the air conditioner's vent to the closed position.

Cooling coils have iced up. • See Air Conditioner Freezing Up below.

Ice blocks the air flow and • Set the mode control at High Fan or High Cool with

Air conditioner

stops the air conditioner

the high temperature.

freezing up

from cooling the room.

 

 

 

 

22Room Air Conditioner

Page 22
Image 22
Goldstar LT1230CR owner manual Common Problems and Solutions, Normal Operation, Troubleshooting

LT1230CR specifications

The Goldstar LT1230CR is a state-of-the-art air conditioning unit designed to provide efficient cooling while maximizing energy savings. This model is perfect for residential and commercial spaces, delivering comfort even during the hottest summer days. With its sleek design, the Goldstar LT1230CR not only performs well but also enhances the aesthetic appeal of any room.

One of the standout features of the Goldstar LT1230CR is its powerful cooling capacity. The unit is equipped with a robust compressor and advanced cooling technology, allowing it to quickly lower the temperature in larger spaces. With a cooling power rating of 12,000 BTU, it is ideal for rooms ranging from 400 to 550 square feet, making it a versatile choice for homes, offices, and other applications.

The Goldstar LT1230CR also includes an energy-efficient rating, making it an environmentally friendly option. The unit is designed to consume less power while delivering optimal performance, resulting in lower electricity bills. With the increasing importance of energy efficiency, this air conditioner complies with Energy Star standards, ensuring that users can enjoy comfort without compromising on sustainability.

Featuring a user-friendly interface, the Goldstar LT1230CR boasts a digital display and remote control for convenient operation. The programmable timer and adjustable thermostat allow users to customize their cooling preferences and set specific schedules, enhancing overall convenience and comfort. Additionally, multiple fan speeds and cooling modes ensure that the unit can adapt to changing weather conditions, providing personalized comfort regardless of the season.

The LT1230CR also incorporates advanced filtration technology, which improves indoor air quality. It comes with a washable and reusable filter that effectively captures dust, allergens, and other pollutants, ensuring that the air circulated in the room is clean and fresh. Regular maintenance is made easy, allowing users to improve the lifespan and efficiency of the unit.

Furthermore, the Goldstar LT1230CR is designed for quiet operation, minimizing noise disruptions, which is especially beneficial in residential environments. This combination of features, technologies, and characteristics makes the Goldstar LT1230CR a top choice for anyone seeking a reliable and efficient air conditioning solution. Whether for a small apartment or a larger office space, this model provides a perfect blend of performance and convenience.